Several methods have been developed since the 1990s, most of which rely upon sensors deployed on overhead lines to measure parameters in real-time. Other systems utilize weather stations that monitor environmental conditions without contacting the line. Data received from any method is reported to a main computer for processing.
In smaller SCADA systems, the supervisory computer may be composed of a single PC, in which case the HMI is a part of this computer. In larger SCADA systems, the master station may include several HMIs hosted on client computers, multiple servers for data acquisition, distributed software applications, and disaster recovery sites.
Ignition is an Integrated Software Platform for SCADA systems released by Inductive Automation in January 2010. It is based on a SQL Database-centric architecture . Ignition features cross-platform , web-based deployment through its integrated web server platform Perspective [ 1 ] , and also dedicated client software utilizing a Java Swing ...
Outage management systems are also commonly integrated with SCADA systems which can automatically report the operation of monitored circuit breakers and other intelligent devices such as SCADA reclosers. Another system that is commonly integrated with an outage management system is a mobile data system. This integration provides the ability for ...
The OPC Data Access Specification is the first of a group of specifications known as the OPC Classic Specifications. [1]OPC Data Access is a group of client–server standards that provides specifications for communicating real-time data from data acquisition devices such as PLCs to display and interface devices like Human–Machine Interfaces (HMI), SCADA systems [2] and also ERP/MES systems. [3]
The goal of Advanced Distribution Automation is real-time adjustment to changing loads, generation, and failure conditions of the distribution system, usually without operator intervention. This necessitates control of field devices, which implies enough information technology (IT) development to enable automated decision making in the field ...
RAPIEnet – Real-time Automation Protocols for Industrial Ethernet; Honeywell SDS – Smart Distributed System – Originally developed by Honeywell. Currently supported by Holjeron. SERCOS III, Ethernet-based version of SERCOS real-time interface standard; SERCOS interface, Open Protocol for hard real-time control of motion and I/O; GE SRTP ...
EPRI (2005) Advanced Control Room Energy Management System: Requirements and Implementation Guidance. Palo Alto, CA. EPRI report 1010076. EEMUA 191 Alarm Systems – A Guide to Design, Management and Procurement (1999) ISBN 0-85931-076-0; ASM Consortium (2009) – Effective Alarm Management Practices ISBN 978-1-4421-8425-1