In-house BPL is broadband access within a building or structure using the electric lines of the structure to provide the network infrastructure. Access BPL is the use of electrical transmission lines to deliver broadband to the home. Access BPL is considered a viable alternative to Cable or DSL to provide the 'final mile' of broadband to end users.
Using the same wiring scheme at each end yields a straight-through cable (a given color wire connects to a given number pin, the same at both ends). In this case, the terminations are identical, so only one pinout is required. In a crossover cable, pins do not correspond – some or all of the conductors are swapped at the terminations.
When two nodes having the same type of ports need to be connected, a crossover cable may be required, especially for older equipment. Connecting nodes having different types of ports (i.e., MDI to MDI-X and vice versa) requires a straight-through cable. Thus connecting an end host to a hub or switch requires a straight-through cable.
A crossover cable may also be used to connect two hubs or two switches on their upstream ports. Because the only difference between the T568A and T568B pin and pair assignments are that pairs 2 and 3 are swapped, a crossover cable may be envisioned as a cable with one modular connector following T568A and the other T568B (see TIA/EIA-568 wiring ...
Backbone cabling is the inter-building and intra-building cable connections in structured cabling between entrance facilities, equipment rooms and telecommunications closets. Backbone cabling consists of the transmission media, main and intermediate cross-connects and terminations at these locations.
A typical rubber sheath cable. The conductors are actually copper but are coated and look silver. Cross section. Note the solid core center earth wire and multi strand power wires. Tough rubber-sheathed cable is a type of cable which normally consists of a black outer sheath of rubber with several conductors inside. The rubber provides an ...
Cables are similar to twisted pair in that many cores are bundled into the same cable but only one conductor is provided per circuit and there is no twisting. All the circuits on the same route use a common path for the return current (earth return). There is a power transmission version of single-wire earth return in use in many locations.
High voltage is defined as any voltage over 1000 volts. [3] Those of 2 to 33 kV are usually called medium voltage cables, those over 50 kV high voltage cables.. Modern HV cables have a simple design consisting of a few parts: the conductor, the conductor shield, the insulation, the insulation shield, the metallic shield, and the jacket.