K-Series Joists are standardized regarding depths, spans, and load-carrying capacities. There are 63 separate designations in the Load Tables, representing joist depths from 10 inches (250 mm) through 30 inches (760 mm) in 2 inches (51 mm) increments and spans through 60 feet (18,000 mm).
A double floor is a floor framed with joists supported by larger timbers.. In traditional timber framing there may be a single set of joists which carry both a floor and ceiling called a single floor (single joist floor, single framed floor) or two sets of joists, one carrying the floor and another carrying the ceiling called a double floor (double framed floor).
Cellular beam is a further development of the traditional castellated beam. [1] The advantage of the steel beam castellation process is that it increases strength without adding weight, making both versions an inexpensive solution to achieve maximum structural load capacity in building construction.
As of 2005, approximately 50% of all wood light framed floors used I-joists. [2] [clarification needed] I-joists were designed to help eliminate typical problems that come with using solid lumber as joists. The advantage of I-joists is they are less likely to bow, crown, twist, cup, check, or split as would a piece of dimensional lumber. I ...
In engineering, span is the distance between two adjacent structural supports (e.g., two piers) of a structural member (e.g., a beam). Span is measured in the horizontal direction either between the faces of the supports (clear span) or between the centers of the bearing surfaces (effective span): [1] A span can be closed by a solid beam or by ...
I-joists, I-beams engineered from wood with fiberboard or laminated veneer lumber, or both, are also becoming increasingly popular in construction, especially residential, as they are both lighter and less prone to warping than solid wooden joists. However, there has been some concern as to their rapid loss of strength in a fire if unprotected.
The height of the ribs and beams should be 1 ⁄ 25 of the span between columns. [3] The width of the solid area around the column should be 1 ⁄ 8 of the span between columns. Its height should be the same as the ribs. [3] Diagram showing waffle slab rib and Beam Heights rule of thumb formulas.
Engineered lumber can be cut to length and installed much like sawn lumber; the flitch requires shop fabrication and/or field bolting. This, coupled with a much increased self-weight of the beam (11.4 pounds (5.2 kg) for engineered wood vs. 25.2 pounds (11.4 kg) for a flitch beam), decreases the viability of the system.