enow.com Web Search

  1. Ads

    related to: dual run vs start capacitor calculator for generator reviews

Search results

  1. Results from the WOW.Com Content Network
  2. Motor capacitor - Wikipedia

    en.wikipedia.org/wiki/Motor_capacitor

    A typical motor start capacitor. A motor capacitor [1] [2] is an electrical capacitor that alters the current to one or more windings of a single-phase alternating-current induction motor to create a rotating magnetic field. [citation needed] There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run ...

  3. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    For a machine to run as an asynchronous generator, capacitor bank must supply minimum 4567 / 3 phases = 1523 VAR per phase. Voltage per capacitor is 440 V because capacitors are connected in delta. Capacitive current Ic = Q/E = 1523/440 = 3.46 A Capacitive reactance per phase Xc = E/Ic = 127 Ω. Minimum capacitance per phase:

  4. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    A feature in the generator mode in parallel to the grid is that the rotor speed is higher than in the driving mode. Then active energy is being given to the grid. [2] Another disadvantage of the induction motor generator is that it consumes a significant magnetizing current I 0 = (20–35)%.

  5. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    A specific model of a generator operated as a standby generator may only need to operate for a few hours per year, but the same model operated as a prime power generator must operate continuously. When running, the standby generator may be operated with a specified - e.g. 10% overload that can be tolerated for the expected short running time.

  6. Doubly fed electric machine - Wikipedia

    en.wikipedia.org/wiki/Doubly_fed_electric_machine

    The doubly fed generator rotors are typically wound with 2 to 3 times the number of turns of the stator. This means that the rotor voltages will be higher and currents respectively lower. Thus in the typical ±30% operational speed range around the synchronous speed, the rated current of the converter is accordingly lower which leads to a lower ...

  7. Applications of capacitors - Wikipedia

    en.wikipedia.org/wiki/Applications_of_capacitors

    The start capacitor is typically mounted to the side of the motor housing. These are called capacitor-start motors, and have relatively high starting torque. There are also capacitor-run induction motors which have a permanently connected phase-shifting capacitor in series with a second winding. The motor is much like a two-phase induction motor.

  8. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    An engine–generator is the combination of an electrical generator and an engine (prime mover) mounted together to form a single piece of equipment. This combination is also called an engine–generator set or a gen-set. In many contexts, the engine is taken for granted and the combined unit is simply called a generator. An engine–generator ...

  9. AC motor - Wikipedia

    en.wikipedia.org/wiki/AC_motor

    [19] [20] [21] A capacitor-start, capacitor-run motor has two separate capacitors, one for starting the motor, and another for running it, and has a centrifugal switch to disconnect the starting capacitor, or a back-EMF relay connected in parallel with the auxiliary winding of the motor. This motor provides high starting torque and high efficiency.

  1. Ads

    related to: dual run vs start capacitor calculator for generator reviews