Smoke dampers can be activated by the fire alarm system, usually initiated by smoke detectors, or interlocked with a fire suppression system. Smoke dampers close by an electric or pneumatic actuator, or a spring actuator, and can be either manually reset or driven open on a reset signal to the electric or pneumatic actuator.
Know your customer (KYC) guidelines and regulations in financial services require professionals to verify the identity, suitability, and risks involved with maintaining a business relationship with a customer. The procedures fit within the broader scope of anti-money laundering (AML) and counter terrorism financing (CTF) regulations.
Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...
This rating is the requirement for protecting paper documents. Above 350 °F (176.7 °C) paper is distorted by the heat and information is lost. A Class 350-4 Hour vault must keep the temperature below 350 °F. for at least four hours, with temperatures up to 2,000 °F. (1,093.3 °C) outside the vault.
Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]
This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...
Purple-K, also known as PKP, is a dry-chemical fire suppression agent used in some dry chemical fire extinguishers. [1] It is the second most effective dry chemical in fighting class B (flammable liquid) fires after Monnex (potassium allophanate), and can be used against some energized electrical equipment fires (USA class C fires). [2]
It is a highly effective fire suppression method for class A, B, C, E and F (as is the case for most fire-extinguishing agents, it is not applicable to metal fires – class D). [1] Some aerosol-generating compounds (e.g., potassium nitrate -based) produce a corrosive by-product that may damage electronic equipment, although later generations ...