Results from the WOW.Com Content Network
The IPS number (reference to an OD) is the same as the NPS number, but the schedules were limited to Standard Wall (STD), Extra Strong, (XS) and Double Extra Strong (XXS). STD is identical to Schedule 40 for NPS 1/8 to NPS 10, inclusive, and indicates .375" wall thickness for NPS 12 and larger.
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
The history of copper pipe is similar. In the 1930s, the pipe was designated by its internal diameter and a 1 ⁄ 16-inch (1.6 mm) wall thickness. Consequently, a 1-inch (25 mm) copper pipe had a 1 + 1 ⁄ 8-inch (28.58 mm) outside diameter. The outside diameter was the important dimension for mating with fittings.
Both standards require use of polyurethane foam for thermal insulation and HDPE for casing. Insulated pipelines are usually assembled from pipes of 6 metres (20 ft), 12 metres (39 ft), or 16 metres (52 ft) in length, directly buried in soil in depths of commonly 0.6–1.2 metres (2 ft 0 in – 3 ft 11 in).
Standard dimension ratio (SDR) is a method of rating a pipe's durability against pressure. The standard dimension ratio describes the correlation between the pipe dimension and the thickness of the pipe wall. [1] Common nominations are SDR11, SDR17, SDR26 and SDR35. Pipes with a lower SDR can withstand higher pressures.
Thicknesses of thermal pipe insulation used for saving energy vary, but as a general rule, pipes operating at more-extreme temperatures exhibit a greater heat flow and larger thicknesses are applied due to the greater potential savings. [3] The location of pipework also influences the selection of insulation thickness.
Specified Minimum Yield Strength (SMYS) means the specified minimum yield strength for steel pipe manufactured in accordance with a listed specification 1. This is a common term used in the oil and gas industry for steel pipe used under the jurisdiction of the United States Department of Transportation .
A pipe support or pipe hanger is a designed element that transfer the load from a pipe to the supporting structures. The load includes the weight of the pipe proper, the content that the pipe carries, all the pipe fittings attached to pipe, and the pipe covering such as insulation. The four main functions of a pipe support are to anchor, guide ...