A fire in an oxygen tube approaching an oxygen firebreak. An oxygen firebreak, also known as a fire stop valve or fire safety valve, is a thermal fuse designed to extinguish a fire in the delivery tube being used by a patient on oxygen therapy and stop the flow of oxygen if the tube is accidentally ignited.
An oxygen concentrator is a device that concentrates the oxygen from a gas supply (typically ambient air) by selectively removing nitrogen to supply an oxygen-enriched product gas stream. They are used industrially, to provide supplemental oxygen at high altitudes, and as medical devices for oxygen therapy .
Medical oxygen storage tanks at the Royal Women's Hospital, Melbourne, Australia. Oxygen may be used for patients requiring supplemental oxygen via mask. Usually accomplished by a large storage system of liquid oxygen at the hospital which is evaporated into a concentrated oxygen supply, pressures are usually around 345–380 kPa (50.0–55.1 psi), [1] [2] or in the UK and Europe, 4–5 bar ...
A resuscitator is a device using positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated and alive. [citation needed] There are three basic types: a manual version (also known as a bag valve mask) consisting of a mask and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank.
UL 67377 Oxygen Reduction Fire Prevention System Units [10] BSI PAS 95:2011 - Hypoxic air fire prevention systems. Specification [4] VdS 3527en:2007 - Inerting and Oxygen Reduction Systems, Planning and Installation [11] Austrian Standards International. ÖNORM F 3073: Planning, engineering, assembly, commissioning and servicing of oxygen ...
Portable oxygen concentrator used with bottle humidifier POCs operate on the same principle as a home concentrator, pressure swing adsorption . [ 6 ] The basic set up of a POC is a miniaturized air compressor , a cylinder filled containing the sieve, a pressure equalizing reservoir and valves and tubes.
An open-circuit SCBA does not recirculate air; it instead allows respired air to be exhausted outside. While 30 CFR 11 does not restrict the gas that can be used (although compressed air is usually chosen), use of compressed oxygen is not allowed due to the system's exposure to outside air. Duration is usually limited to 30-60 minutes.
A gas non-return valve (NV), which: prevents dangerous gas mixtures. ensures the gas only flows in the intended direction. and a flame arrestor (FA), which: cools the flame to below the ignition temperature of the gas or gas mixture. prevents flashback. In addition to these two basic safety functions a flashback arrestor can also have a: