  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The resistance path is the total resistance back through the supply transformer; to measure this an engineer will use an "earth fault loop impedance meter". The application of a low voltage allows a small current to pass from the socket back through earth to the supply transformer and distribution board.

  3. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    Live testing. Earth fault loop impedance testing: this test is to check that if a fault did occur, that the system meets requirements to cause a disconnection of the supply within the time limit specified by standards Insulation resistance testing Polarity test: a test to check that the connections are connected in the right sequence

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    A ground fault (earth fault) is any failure that allows unintended connection of power circuit conductors with the earth. [citation needed] Such faults can cause objectionable circulating currents, or may energize the housings of equipment at a dangerous voltage. Some special power distribution systems may be designed to tolerate a single ...

  5. Multifunction tester - Wikipedia

    en.wikipedia.org/wiki/Multifunction_tester

    Multifunction testers are able to perform continuity tests (or low ohms resistance tests) and insulation resistance tests (or high ohms resistance tests) and they may also be able to perform earth fault loop impedance tests, prospective short-circuit current tests, earth electrode tests and RCD tests.

  6. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    Ground loop current induced by stray AC magnetic fields (B, green) Ground loop currents can be induced by stray AC magnetic fields [5] [7] (B, green) which are always present around AC electrical wiring. The ground loop constitutes a conductive wire loop which may have a large area of several square meters.

  7. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    In an electrical grid, the short circuit ratio (or SCR) is the ratio of: the short circuit apparent power (SCMVA) in the case of a line-line-line-ground (3LG) fault at the location in the grid where some generator is connected, to: the power rating of the generator itself (GMW).

  8. Murray loop bridge - Wikipedia

    en.wikipedia.org/wiki/Murray_loop_bridge

    Murray loop bridge Leeds & Northrup test instrument capable of performing Murray and Varley loop tests. The Murray loop bridge is a bridge circuit used for locating faults in underground or underwater cables. [1] [2] It has been used for more than 100 years [3] but is being replaced by the more precise Time-domain reflectometer.

  9. Earth potential rise - Wikipedia

    en.wikipedia.org/wiki/Earth_potential_rise

    In electrical engineering, earth potential rise (EPR), also called ground potential rise (GPR), occurs when a large current flows to earth through an earth grid impedance. The potential relative to a distant point on the Earth is highest at the point where current enters the ground, and declines with distance from the source.