enow.com Web Search

  1. Ads

    related to: calculate earth fault loop impedance tester for sale

Search results

  1. Results from the WOW.Com Content Network
  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The resistance path is the total resistance back through the supply transformer; to measure this an engineer will use an "earth fault loop impedance meter". The application of a low voltage allows a small current to pass from the socket back through earth to the supply transformer and distribution board.

  3. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    Live testing. Earth fault loop impedance testing: this test is to check that if a fault did occur, that the system meets requirements to cause a disconnection of the supply within the time limit specified by standards Insulation resistance testing Polarity test: a test to check that the connections are connected in the right sequence

  4. Multifunction tester - Wikipedia

    en.wikipedia.org/wiki/Multifunction_tester

    Multifunction testers are able to perform continuity tests (or low ohms resistance tests) and insulation resistance tests (or high ohms resistance tests) and they may also be able to perform earth fault loop impedance tests, prospective short-circuit current tests, earth electrode tests and RCD tests.

  5. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    A ground fault (earth fault) is any failure that allows unintended connection of power circuit conductors with the earth. [citation needed] Such faults can cause objectionable circulating currents, or may energize the housings of equipment at a dangerous voltage. Some special power distribution systems may be designed to tolerate a single ...

  6. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    Ground loop current induced by stray AC magnetic fields (B, green) Ground loop currents can be induced by stray AC magnetic fields [5] [7] (B, green) which are always present around AC electrical wiring. The ground loop constitutes a conductive wire loop which may have a large area of several square meters.

  7. Megger Group Limited - Wikipedia

    en.wikipedia.org/wiki/Megger_Group_Limited

    Digital line earth loop impedance tester 1985 Microprocessor-based high current test set 1989 Battery impedance test equipment (BITE) 1990 Automatic 10kV insulation power factor test set 1990 Microprocessor-based protective relay test set 1994 DSP-driven watthour meter test set 1996 Windows-based Testing Software Program 1999

  1. Ads

    related to: calculate earth fault loop impedance tester for sale