  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load. These include the global coordinates of the site and the size of the structure. [1] [5]

  3. List of conversion factors - Wikipedia

    en.wikipedia.org/wiki/List_of_conversion_factors

    1 atm × 1 cu ft/h = 0.797 001 247 04 W: atmosphere-cubic foot per minute: atm cfm [citation needed] ≡ 1 atm × 1 cu ft/min = 47.820 074 682 24 W: atmosphere-cubic foot per second: atm cfs [citation needed] ≡ 1 atm × 1 cu ft/s = 2.869 204 480 9344 × 10 3 W: BTU (International Table) per hour: BTU IT /h ≡ 1 BTU IT /h ≈ 0.293 071 W

  4. British thermal unit - Wikipedia

    en.wikipedia.org/wiki/British_thermal_unit

    In the United States and Canada, the R-value that describes the performance of thermal insulation is typically quoted in square foot degree Fahrenheit hours per British thermal unit (ft 2 ⋅°F⋅h/Btu). For one square foot of the insulation, one Btu per hour of heat flows across the insulator for each degree of temperature difference across it.

  5. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F) Within this article, U-values are expressed in SI unless otherwise noted. To convert from SI to US customary values, divide by 5.678. [1]

  6. Equivalence of direct radiation - Wikipedia

    en.wikipedia.org/wiki/Equivalence_of_direct...

    Equivalence of direct radiation (EDR) is a standardized comparison method for estimating the output ability of space-heating radiators and convectors.. Measured in square feet, the reference standard for EDR is the mattress radiator [1] invented by Stephen J. Gold in the mid 19th century.

  7. Therm - Wikipedia

    en.wikipedia.org/wiki/Therm

    The therm (symbol, thm) is a non-SI unit of heat energy equal to 100,000 British thermal units (BTU), [1] and approximately 105 megajoules, 29.3 kilowatt-hours, 25,200 kilocalories and 25.2 thermies. One therm is the energy content of approximately 100 cubic feet (2.83 cubic metres) of natural gas at standard temperature and pressure .

  8. List of thermal conductivities - Wikipedia

    en.wikipedia.org/wiki/List_of_thermal_conductivities

    Also the copy is blurred up enough to give you the impression that maybe what it really means is 1.36 W −1 cm −1 K −1 and 78.6 Btu hr1 ft1 F −1 and a type-head that got overdue for its cleaning since the secretary had a tall heap of papers on her desk and if that is the case then the multilingual expression is perfectly ...

  9. Thermal design power - Wikipedia

    en.wikipedia.org/wiki/Thermal_design_power

    The formula relating all these parameters, given by AMD, is the usual T P D = ( T c − T a ) / R c a {\displaystyle TPD=(Tc-Ta)/Rca} The declared TPDs of these devices range from 65 W to 105 W; the ambient temperature considered by AMD is +42° C , and the case temperatures range from +61.8 °C to +69.3 °C , while the case-to-ambient thermal ...