Search results
Results from the WOW.Com Content Network
Will change OperandSize from 16-bit to 32-bit if CS.D=0, or from 32-bit to 16-bit if CS.D=1. 67h: AddressSize override. Will change AddressSize from 16-bit to 32-bit if CS.D=0, or from 32-bit to 16-bit if CS.D=1. The 80386 also introduced the two new segment registers FS and GS as well as the x86 control, debug and test registers.
The x86 processors support five modes of operation for x86 code, Real Mode, Protected Mode, Long Mode, Virtual 86 Mode, and System Management Mode, in which some instructions are available and others are not. A 16-bit subset of instructions is available on the 16-bit x86 processors, which are the 8086, 8088, 80186, 80188, and 80286.
The BT x86 assembly language instruction stands for Bit Test and was added to the x86 instruction set with the 80386 processor. BT copies a bit from a given register to the carry flag. [1] Example: copy the third least significant bit from EAX to the carry flag
In the x86 assembly language, the TEST instruction performs a bitwise AND on two operands. The flags SF, ZF, PF are modified while the result of the AND is discarded. The OF and CF flags are set to 0, while AF flag is undefined. There are 9 different opcodes for the TEST instruction depending on the type and size of the operands. It can compare ...
The aged 32-bit x86 was competing with much more advanced 64-bit RISC architectures which could address much more memory. Intel and the whole x86 ecosystem needed 64-bit memory addressing if x86 was to survive the 64-bit computing era, as workstation and desktop software applications were soon to start hitting the limits of 32-bit memory ...
The FLAGS register is the status register that contains the current state of an x86 CPU.The size and meanings of the flag bits are architecture dependent. It usually reflects the result of arithmetic operations as well as information about restrictions placed on the CPU operation at the current time.
While what these instructions do is similar to bit level gather-scatter SIMD instructions, PDEP and PEXT instructions (like the rest of the BMI instruction sets) operate on general-purpose registers. [12] The instructions are available in 32-bit and 64-bit versions. An example using arbitrary source and selector in 32-bit mode is:
The primary defining characteristic of IA-32 is the availability of 32-bit general-purpose processor registers (for example, EAX and EBX), 32-bit integer arithmetic and logical operations, 32-bit offsets within a segment in protected mode, and the translation of segmented addresses to 32-bit linear addresses. The designers took the opportunity ...