enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Coaxial cable - Wikipedia

    en.wikipedia.org/wiki/Coaxial_cable

    Coaxial cable, or coax (pronounced / ˈkoʊ.æks /), is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric (insulating material); many coaxial cables also have a protective outer sheath or jacket. The term coaxial refers to the inner conductor and the ...

  3. Electrical length - Wikipedia

    en.wikipedia.org/wiki/Electrical_length

    Massive. v. t. e. In electrical engineering, electrical length is a dimensionless parameter equal to the physical length of an electrical conductor such as a cable or wire, divided by the wavelength of alternating current at a given frequency traveling through the conductor. [ 1 ][ 2 ][ 3 ] In other words, it is the length of the conductor ...

  4. Transmission line - Wikipedia

    en.wikipedia.org/wiki/Transmission_line

    Transmission line. Schematic of a wave moving rightward down a lossless two-wire transmission line. Black dots represent electrons, and the arrows show the electric field. One of the most common types of transmission line, coaxial cable. In electrical engineering, a transmission line is a specialized cable or other structure designed to conduct ...

  5. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    To match the impedances, both cables must be connected to a matching transformer with a turns ratio of 2:1. In this example, the 300-ohm line is connected to the transformer side with more turns; the 75-ohm cable is connected to the transformer side with fewer turns. The formula for calculating the transformer turns ratio for this example is:

  6. Heaviside condition - Wikipedia

    en.wikipedia.org/wiki/Heaviside_condition

    Heaviside's model of a transmission line. A transmission line can be represented as a distributed-element model of its primary line constants as shown in the figure. The primary constants are the electrical properties of the cable per unit length and are: capacitance C (in farads per meter), inductance L (in henries per meter), series resistance R (in ohms per meter), and shunt conductance G ...

  7. Catenary - Wikipedia

    en.wikipedia.org/wiki/Catenary

    If the weight of the roadway per unit length is w and the weight of the cable and the wire supporting the bridge is negligible in comparison, then the weight on the cable (see the figure in Catenary#Model of chains and arches) from c to r is wx where x is the horizontal distance between c and r. Proceeding as before gives the differential equation

  8. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    IEC 60228 is the International Electrotechnical Commission (IEC)'s international standard on conductors of insulated cables. As of 2023 the current version is Third Edition 2004-11 [1] Among other things, it defines a set of standard wire cross-sectional areas: In engineering applications, it is often most convenient to describe a wire in terms ...

  9. Differential signalling - Wikipedia

    en.wikipedia.org/wiki/Differential_signalling

    SCSI-1 variations included a high voltage differential (HVD) implementation whose maximum cable length was many times that of the single-ended version. SCSI equipment, for example, allows a maximum total cable length of 25 meters using HVD, while single-ended SCSI allows a maximum cable length of 1.5 to 6 meters, depending on bus speed.