Ads
related to: vfd braking torque specifications table
Search results
Results from the WOW.Com Content Network
A braking chopper is an magnetical switch that limits the DC bus voltage by switching the braking energy to a resistor where the braking energy is converted to heat. Braking choppers are automatically activated when the actual DC bus voltage exceeds a specified level depending on the nominal voltage of the variable-frequency drive
Small variable-frequency drive Chassis of above VFD (cover removed). A variable-frequency drive (VFD, or adjustable-frequency drive, adjustable-speed drive, variable-speed drive, AC drive, micro drive, inverter drive, variable voltage variable frequency drive, or drive) is a type of AC motor drive (system incorporating a motor) that controls speed and torque by varying the frequency of the ...
Vector control, also called field-oriented control (FOC), is a variable-frequency drive (VFD) control method in which the stator currents of a three-phase AC or brushless DC electric motor are identified as two orthogonal components that can be visualized with a vector. One component defines the magnetic flux of the motor, the other the torque ...
Direct torque control (DTC) is one method used in variable-frequency drives to control the torque (and thus finally the speed) of three-phase AC electric motors.This involves calculating an estimate of the motor's magnetic flux and torque based on the measured voltage and current of the motor.
The torque on shaft is 0.0053 N⋅m at 2 A because of the assumed radius of the rotor (exactly 1 m). Assuming a different radius would change the linear K v {\displaystyle K_{\text{v}}} but would not change the final torque result.
When changing VFD frequency in standard low-performance variable-torque applications using Volt-per-Hertz (V/Hz) control, the AC motor's voltage-to-frequency ratio can be maintained constant, and its power can be varied, between the minimum and maximum operating frequencies up to a base frequency. Constant voltage operation above base frequency ...
The braking current decays, and after a delay of about 1.5 seconds the braking relay contactor opens again. At this point the motor can be restarted. In such a unit, there are typically two potentiometers, one to vary the braking torque from the firing circuit and the other to vary the timer. These settings are balanced so that braking torque ...
For the tests the vehicle brake for which the replacement linings are designed is installed in an inertia dynamometer instrumented for continuous recording of rotative speed, brake torque, brake line pressure, number of rotations after brake application, braking time, and brake rotor temperature. [1]
Ads
related to: vfd braking torque specifications table