From NFPA 72, 2002 Edition: “7.4.2.1* To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater ...
The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.
The NFPA 72 (National Fire Alarm and Signaling Code) is a standard published by the National Fire Protection Association every 3 years for installation of fire alarm systems and emergency communication systems in the United States.
The Life Safety Code (NFPA 101), passed by the US National Fire Protection Association (NFPA) in 1976, first required smoke alarms in homes. [10] Smoke alarm sensitivity requirements in UL 217 were modified in 1985 to reduce susceptibility to nuisance alarms. [10]
In the United States, the National Fire Protection Association sets standards for PASS devices in NFPA 1982. [ 1 ] The PASS device is normally used in conjunction with breathing apparatus; it is a small, battery-powered device attached to the self-contained breathing apparatus (SCBA) harness which enables the firefighter to summon help by ...
Fire alarm systems are required in most commercial buildings. They may include smoke detectors, heat detectors, and manual fire alarm activation devices (pull stations). All components of a fire alarm system are connected to a fire alarm control panel. Fire alarm control panels are usually found in an electrical or panel room.
The alarm transmission methods covered under UL 365 can be categorized under standard line security or encrypted line security. The systems are required to operate within the limits of Class 2 remote control and signal circuits as defined by the National Electrical Code, NFPA 70. [15]
A fire truck running the E-Q2B siren. Today Federal Signal's Q2B siren is still in wide use. The majority of users of the Q Siren are fire departments, although some ambulances and heavy rescue squads have employed the Q-siren. The Q-siren produces 123 decibels at 10 feet (3.0 m) with an operating current of 100 amps at 12 V DC (1.2 kW). [1]