enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    The HSPF is related to the non-dimensional Coefficient of Performance (COP) for a heat pump, which measures the ratio of heat delivered to work done by the compressor. The HSPF can be converted to a seasonally-averaged COP assuming a lossless compressor and no heat loss by multiplying by the heat/energy equivalence factor .29307111 W·h per BTU.

  3. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The COP usually exceeds 1, especially in heat pumps, because instead of just converting work to heat (which, if 100% efficient, would be a COP of 1), it pumps additional heat from a heat source to where the heat is required. Most air conditioners have a COP of 3.5 to 5. [3]

  4. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    Specifically, the heat pump transfers thermal energy using a heat pump and refrigeration cycle, cooling the cool space and warming the warm space. [1] In winter a heat pump can move heat from the cool outdoors to warm a house; the pump may also be designed to move heat from the house to the warmer outdoors in summer.

  5. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  6. Absorption heat pump - Wikipedia

    en.wikipedia.org/wiki/Absorption_heat_pump

    The absorption heat pump can be used as a cooler during summer while, during winter, it can be used on heat pump or heat transformer mode according to the available heat source. [6] The performance of the absorption heat pump is indicated by the coefficient of performance (COP). The COP is the ratio of the removed (for refrigeration) or ...

  7. Direct exchange geothermal heat pump - Wikipedia

    en.wikipedia.org/wiki/Direct_exchange_geothermal...

    DX system being drilled in the 1980s. A direct exchange (DX) geothermal heat pump is a type of ground source heat pump in which refrigerant circulates through copper tubing placed in the ground unlike other ground source heat pumps where refrigerant is restricted to the heat pump itself with a secondary loop in the ground filled with a mixture of water and anti-freeze.

  8. Pinch analysis - Wikipedia

    en.wikipedia.org/wiki/Pinch_analysis

    This is where the design is most constrained. Hence, by finding this point and starting the design there, the energy targets can be achieved using heat exchangers to recover heat between hot and cold streams in two separate systems, one for temperatures above pinch temperatures and one for temperatures below pinch temperatures. In practice ...

  9. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    In the United States, the efficiency of air conditioners is often rated by the seasonal energy efficiency ratio (SEER) which is defined by the Air Conditioning, Heating, and Refrigeration Institute, a trade association, in its 2008 standard AHRI 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment. [1]