Search results
Results from the WOW.Com Content Network
An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).
Current limiting reactors, once called current limiting reactance coils, were first presented in 1915. [2] The inventor of the current limiting reactance coil was Vern E. Alden who filed the patent on November 20, 1917 with an issue date of September 11, 1923. The original assignee was Westinghouse Electric & Manufacturing Company. [3]
An inrush current limiter is a component used to limit inrush current to avoid gradual damage to components and avoid blowing fuses or tripping circuit breakers.Negative temperature coefficient (NTC) thermistors and fixed resistors are often used to limit inrush current.
A current-limiting circuit is usually used to limit maximum primary tank current (which must be switched by the IGBTs) to a safe level. Performance of a DRSSTC can be comparable to a medium-power spark-gap Tesla coil, and efficiency (as measured by spark length versus input power) can be significantly greater than a spark-gap Tesla coil ...
The "1.2/50 μs" generator is designed for insulation testing, and produces a high-voltage, low-current impulse into a high-impedance load. The output current of this generator is on the milliampere scale. [2] [5] The "8/20 μs" generator is designed for surge arrester testing, and produces a high-current surge into a low-impedance load. [2]
The upper graph shows the current density as function of the overpotential η . The anodic and cathodic current densities are shown as j a and j c, respectively for α=α a =α c =0.5 and j 0 =1mAcm −2 (close to values for platinum and palladium). The lower graph shows the logarithmic plot for different values of α (Tafel plot).
A simple solution is to add electrical impedance to the circuit. This limits the rate at which current can increase, which limits the level the fault current can rise to before the breaker is opened. However, this also limits the ability of the circuit to satisfy rapidly changing demand, so the addition or removal of large loads causes unstable ...
The limiting current in electrochemistry is the limiting value of a faradaic current that is approached as the rate of charge transfer to an electrode is increased. The limiting current can be approached, for example, by increasing the electric potential or decreasing the rate of mass transfer to the electrode. It is independent of the applied ...