enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Sample preparation in mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Sample_preparation_in_mass...

    Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration , sample phase, and composition of the analyte solution.

  3. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Ion mobility spectrometry-mass spectrometry (IMS/MS or IMMS) is a technique where ions are first separated by drift time through some neutral gas under an applied electrical potential gradient before being introduced into a mass spectrometer. [43] Drift time is a measure of the collisional cross section relative to the charge of the ion.

  4. Selected reaction monitoring - Wikipedia

    en.wikipedia.org/wiki/Selected_reaction_monitoring

    Selected reaction monitoring (SRM), also called multiple reaction monitoring (MRM), is a method used in tandem mass spectrometry in which an ion of a particular mass is selected in the first stage of a tandem mass spectrometer and an ion product of a fragmentation reaction of the precursor ions is selected in the second mass spectrometer stage ...

  5. Mass spectral interpretation - Wikipedia

    en.wikipedia.org/wiki/Mass_spectral_interpretation

    [1] [2] Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass spectrometry. [3] [4] Organic chemists obtain mass spectra of chemical compounds as part of structure elucidation and the analysis is part of many organic chemistry ...

  6. Mass chromatogram - Wikipedia

    en.wikipedia.org/wiki/Mass_chromatogram

    A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.

  7. De novo peptide sequencing - Wikipedia

    en.wikipedia.org/wiki/De_novo_peptide_sequencing

    The mass of b 2-ion = mass of two amino acid residues + 1. Table 2. Mass of b2-ions in peptide fragmentation [16] Identify a sequence ion series by the same mass difference, which matches one of the amino acid residue masses (see Table 1). For example, mass differences between a n and a n-1, b n and b n-1, c n and c n-1 are the same.

  8. Direct analysis in real time - Wikipedia

    en.wikipedia.org/wiki/Direct_analysis_in_real_time

    In mass spectrometry, direct analysis in real time (DART) is an ion source that produces electronically or vibronically excited-state species from gases such as helium, argon, or nitrogen that ionize atmospheric molecules or dopant molecules. The ions generated from atmospheric or dopant molecules undergo ion-molecule reactions with the sample ...

  9. Pyrolysis–gas chromatography–mass spectrometry is a method of chemical analysis in which the sample is heated to decomposition to produce smaller molecules that are separated by gas chromatography and detected using mass spectrometry. [1] [2]