enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Weatherhead - Wikipedia

    en.wikipedia.org/wiki/Weatherhead

    A weatherhead on a residence in Mount Vernon, Washington, US. A weatherhead, also called a weathercap, service head, service entrance cap, or gooseneck (slang) is a weatherproof service drop entry point where overhead power or telephone wires enter a building, or where wires transition between overhead and underground cables.

  3. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, larger aluminum stranded building wire made with AA-8000 series alloy of aluminum is used for electrical services (e.g. service entrance conductors from the utility connection to the service breaker panel) and for larger branch circuits such as for sub-panels, ranges, clothes dryers and air-conditioning units.

  4. Service drop - Wikipedia

    en.wikipedia.org/wiki/Service_drop

    The service drop provides the building with two 120 V lines of opposite phase, so 240 V can be obtained by connecting a load between the two 120 V conductors, while 120 V loads are connected between either of the two 120 V lines and the neutral line. 240 V circuits are used for high-demand devices, such as air conditioners, water heaters ...

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Electrical panels, cables and firestops in an electrical service room at a paper mill in Ontario, Canada. Electrical panels are easily accessible junction boxes used to reroute and switch electrical services. The term is often used to refer to circuit breaker panels or fuseboxes. Local codes can specify physical clearance around the panels.

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The National Electrical Code (NEC) specifies that the black conductor represent the hot conductor, with significant voltage to earth ground; the white conductor represent the identified or neutral conductor, near ground potential; [11] and the bare/green conductor, the safety grounding conductor not normally used to carry circuit current.

  7. Motor control center - Wikipedia

    en.wikipedia.org/wiki/Motor_control_center

    It may be combined with the electrical service entrance for the building. [ 2 ] MCC's are typically found in large commercial or industrial buildings where there are many electric motors that need to be controlled from a central location, [ 1 ] such as a mechanical room or electrical room .

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    For electrical installations with split-phase (three-wire single-phase) service, the neutral point of the system is at the center-tap on the secondary side of the service transformer. For larger electrical installations, such as those with polyphase service, the neutral point is usually at the common connection on the secondary side of delta ...