enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. File:Power Transformer Maintenance and Acceptance Testing.pdf

    en.wikipedia.org/wiki/File:Power_Transformer...

    Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Donate

  3. Sweep frequency response analysis - Wikipedia

    en.wikipedia.org/wiki/Sweep_frequency_response...

    An initial SFRA test is carried out to obtain the signature of the transformer frequency response by injecting various discreet frequencies. This reference is then used for future comparisons. A change in winding position, degradation in the insulation, etc. will result in change in capacitance or inductance thereby affecting the measured curves.

  4. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 61442 Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) IEC 61443 Short-circuit temperature limits of electric cables with rated voltages above 30 kV (U m = 36 kV) IEC 61445 Digital Test Interchange Format (DTIF)

  5. Megohmmeter - Wikipedia

    en.wikipedia.org/wiki/Megohmmeter

    Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.

  6. HVDC converter station - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter_station

    The insulation of the transformer windings must be specially designed to withstand a large DC potential to earth. Converter transformers can be built as large as 300 Mega volt amperes as a single unit. It is impractical to transport larger transformers, so when larger ratings are required, several individual transformers are connected together.

  7. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    This is done by observing the deviation of the transformer parameters from their expected values. Transformers are the most critical assets of electrical transmission and distribution systems, and their failures could cause power outages, personal and environmental hazards, and expensive rerouting or purchase of power from other suppliers ...

  8. Common Information Model (electricity) - Wikipedia

    en.wikipedia.org/wiki/Common_Information_Model...

    CIM models the network itself using the 'wires model'. It describes the basic components used to transport electricity. Measurements of power are modeled by another class. These measurements support the management of power flow at the transmission level, and by extension, the modeling of power through a revenue meter on the distribution network.

  9. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of the circuit.