enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    EN 1992-1-2 deals with the design of concrete structures for the accidental situation of fire exposure and is intended to be used in conjunction with EN 1992-1-1 and EN 1991-1-2. This part 1-2 only identifies differences from, or supplements to, normal temperature design. Part 1-2 of EN 1992 deals only with passive methods of fire protection.

  3. 3D concrete printing - Wikipedia

    en.wikipedia.org/wiki/3D_concrete_printing

    TU/e Built Environment's Rohaco 3D Concrete Printer being extensively used for Concrete Printing Research. 3D concrete printing, or simply concrete printing, refers to digital fabrication processes for cementitious materials based on one of several different 3D printing technologies. 3D-printed concrete eliminates the need for formwork, reducing material waste and allowing for greater ...

  4. Insulating concrete form - Wikipedia

    en.wikipedia.org/wiki/Insulating_concrete_form

    The first expanded polystyrene ICF Wall forms were developed in the late 1960s with the expiration of the original patent and the advent of modern foam plastics by BASF. [citation needed] Canadian contractor Werner Gregori filed the first patent for a foam concrete form in 1966 with a block "measuring 16 inches high by 48 inches long with a tongue-and-groove interlock, metal ties, and a waffle ...

  5. Shop drawing - Wikipedia

    en.wikipedia.org/wiki/Shop_drawing

    Concrete reinforcing is custom-fabricated from 60-foot-long reinforcing bars. [5] The reinforcing bars are cut to length and bent to specific configurations. The shop drawing and the accompanying “cut sheet” lists the quantity, sizes, lengths, and shapes of the reinforcing bar. [ 5 ]

  6. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    ACI Code 7.10.4.2: For cast-in-place construction, size of spirals shall not be less than 3/8 in. diameter. ACI Code 7.10.4.3: Clear spacing between spirals shall not exceed 3 in., nor be less than 1in. Section 10.9.3 adds an additional lower limit to the amount of spiral reinforcement via the volumetric spiral reinforcement ratio ρ s.

  7. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    A clear distinction is made between the ultimate state (US) and the ultimate limit state (ULS). The Ultimate State is a physical situation that involves either excessive deformations leading and approaching collapse of the component under consideration or the structure as a whole, as relevant, or deformations exceeding pre-agreed values.

  8. Offshore concrete structure - Wikipedia

    en.wikipedia.org/wiki/Offshore_concrete_structure

    Concrete Gravity Base Structures (CGBS) is a further development of the first-generation Condeep drilling/production platforms installed in the North Sea between the late 1970s and mid '90s. The CGBS have no oil storage facilities and the topside installations will be carried out in the field by a float-over mating method.

  9. Construction aggregate - Wikipedia

    en.wikipedia.org/wiki/Construction_aggregate

    In Europe, sizing ranges are specified as d/D, where the d shows the smallest and D shows the largest square mesh grating that the particles can pass. Application-specific preferred sizings are covered in European Standard EN 13043 for road construction, EN 13383 for larger armour stone, EN 12620 for concrete aggregate, EN 13242 for base layers of road construction, and EN 13450 for railway ...