Search results
Results from the WOW.Com Content Network
For an electric machine, the power rating is the number on its rating plate and corresponds to a maximum electric load it can carry. There is a distinction between the continuous rating (for generators, continuous maximum rating or CMR [ 2 ] ), at which the machine can be operational without a time limit and short-term rating that can only be ...
For electrical motors, a similar kind of information is conveyed by the service factor, which is a multiplier that, when applied to the rated output power, gives the power level a motor can sustain for shorter periods of time. The service factor is typically in the 1.15-1.4 range, with the figure being lower for higher-power motors.
motor controller Electrical apparatus that regulates and protects an electric motor, which may be as simple as an on-off switch or a servo system for precision machine tools. motor soft starter A device that reduces the inrush current when an electric motor is first connected to the power supply. MP3 A standard for encoding audio in digital ...
An industrial electric motor . An electric motor is a machine that converts electrical energy into mechanical energy.Most electric motors operate through the interaction between the motor's magnetic field and electric current in a wire winding to generate force in the form of torque applied on the motor's shaft.
If two motors with the same and torque work in tandem, with rigidly connected shafts, the of the system is still the same assuming a parallel electrical connection. The K M {\displaystyle K_{\text{M}}} of the combined system increased by 2 {\displaystyle {\sqrt {2}}} , because both the torque and the losses double.
IEC 60034-30 specifies energy-efficiency classes for single-speed, continuous duty(S1), three-phase, cage-induction motors with 2, 4 or 6 poles. It classifies three classes: IE1 (standard), IE2 (high) and IE3 (premium). For each class the efficiency is defined for a rated output range from 0.75 to 375 kW.
Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others.
In electrical engineering, dot marking convention, or alphanumeric marking convention, or both, can be used to denote the same relative instantaneous polarity of two mutually inductive components such as between transformer windings. These markings may be found on transformer cases beside terminals, winding leads, nameplates, schematic and ...