From this test hydrant, a static pressure and a residual pressure will be measured. The other hydrant, known as the flow hydrant, is usually the nearest hydrant away from the test hydrant. The flow hydrant is fitted with a diffuser device containing a pitot tube that measures stagnation pressure in the middle of the stream while the hydrant is ...
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]
According to NFPA 1963, all U.S. fire hydrants should have the following ports: 2 + 1 ⁄ 2-inch attack port with 2.5-7.5 NH threads (two ports per hydrant; NFPA 1963 requirement) 4 + 1 ⁄ 2-inch pumper (steamer) port with either 4.5-4 NH threads or a 5-inch Storz port (one port per hydrant; NFPA 1963 requirement)
In the United States, the AWWA and NFPA recommend hydrants be colored chrome yellow [6] for rapid identification apart from the bonnet and nozzle caps which should be coded according to their available flow. Class AA hydrants (>1500 gpm) should have their nozzle caps and bonnet colored light blue, Class A hydrants (1000–1499 gpm) green, Class ...
Pressure testing the hose. Standards set by the National Fire Protection Association require that each length of new double jacket, rubber-lined attack hose must be pressure tested to 600 psi (41.4 bar; 4,140 kPa), but most manufacturers test to 800 psi (55.2 bar; 5,520 kPa). Subsequent to delivery, the hose is tested annually to 400 psi (27.6 ...
Used for hydrants with low pressure, attaching multiple engines to one hydrant, or boosting pressure in the intake line to accommodate for friction loss. Hydrant gate A gate valve used to control water flow through one of the discharge ports on a hydrant with two or more ports. Typically, one fire hose is initially connected to one discharge ...
5-inch (13 cm) flex suction hose with Storz fittings, mounted on an engine. Flexible suction hose (Flex suction or suction hose), not to be confused with hard suction hose in U.S., is a specific type of fire hose used in drafting operations, when a fire engine uses a vacuum to draw water from a portable water tank, pool, or other static water source.
In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.