Search results
Results from the WOW.Com Content Network
For a 2 hour GTT with 75 g intake, a glucose level below 7.8 mmol/L (140 mg/dL) is normal, whereas higher levels indicate hyperglycemia. Blood plasma glucose between 7.8 mmol/L (140 mg/dL) and 11.1 mmol/L (200 mg/dL) indicate "impaired glucose tolerance", and levels at or above 11.1 mmol/L at 2 hours confirm a diagnosis of diabetes. [12]
A level below 5.6 mmol/L (100 mg/dL) 10–16 hours without eating is normal. 5.6–6 mmol/L (100–109 mg/dL) may indicate prediabetes and oral glucose tolerance test (OGTT) should be offered to high-risk individuals (old people, those with high blood pressure etc.). 6.1–6.9 mmol/L (110–125 mg/dL) means OGTT should be offered even if other ...
The metabolic response to a carbohydrate challenge is conveniently assessed by a postprandial glucose level drawn 2 hours after a meal or a glucose load. In addition, the glucose tolerance test, consisting of several timed measurements after a standardized amount of oral glucose intake, is used to aid in the diagnosis of diabetes. [citation needed]
In non-diabetic individuals, levels peak at about an hour after the start of a meal, rarely exceed 140 mg/dl, and return to preprandial levels within 2–3 hours. [1] These time-profiles are heavily altered in diabetic patients. [1]
two-hour glucose levels of 140 to 199 mg per dL (7.8 to 11.0 mmol/L) on the 75-g oral glucose tolerance test. A patient is said to be under the condition of IGT when he/she has an intermediately raised glucose level after 2 hours, but less than the level that would qualify for type 2 diabetes mellitus. The fasting glucose may be either normal ...
To assist in diagnosis, a doctor may order an HbA1c test, which measures the blood sugar average over the two or three months before the test. The more specific 6-hour glucose tolerance test can be used to chart changes in the patient's blood sugar levels before ingestion of a special glucose drink and at regular intervals during the six hours ...
Four generations of blood glucose meter, c. 1991–2005. Sample sizes vary from 30 to 0.3 μl. Test times vary from 5 seconds to 2 minutes (modern meters typically require less than 15 seconds). A blood glucose meter is an electronic device for measuring the blood glucose level. A relatively small drop of blood is placed on a disposable test ...
The World Health Organization definition of diabetes (both type 1 and type 2) is for a single raised glucose reading with symptoms, otherwise raised values on two occasions, of either: [65] fasting plasma glucose ≥ 7.0 mmol/L (126 mg/dL) or. glucose tolerance test with two hours after the oral dose a plasma glucose ≥ 11.1 mmol/L (200 mg/dL)