Sample-rate conversion prevents changes in speed and pitch that would otherwise occur when transferring recorded material between such systems. More specific types of resampling include: upsampling or upscaling; downsampling, downscaling, or decimation; and interpolation. The term multi-rate digital signal processing is sometimes used to refer ...
The matched Z-transform method, also called the pole–zero mapping [1] [2] or pole–zero matching method, [3] and abbreviated MPZ or MZT, [4] is a technique for converting a continuous-time filter design to a discrete-time filter (digital filter) design.
The sampling theorem states that sampling frequency would have to be greater than 200 Hz. Sampling at four times that rate requires a sampling frequency of 800 Hz. This gives the anti-aliasing filter a transition band of 300 Hz ((f s /2) − B = (800 Hz/2) − 100 Hz = 300 Hz) instead of 0 Hz if the sampling frequency was 200 Hz. Achieving an ...
[a] But in signal processing, decimation by a factor of 10 actually means keeping only every tenth sample. This factor multiplies the sampling interval or, equivalently, divides the sampling rate. For example, if compact disc audio at 44,100 samples/second is decimated by a factor of 5/4, the
Sample rate Bit rate Bits per sample Latency CBR VBR Stereo Multichannel G.711: companding A-law or μ-law, PCM: 8 kHz 64 kbit/s 8 bit 125 μs (typical) Yes No No No G.711.0: Lossless compression of G.711: 8 kHz 0.2–65.6 kbit/s 8 bit 5–40 ms No Yes No No G.711.1: MDCT, A-law, μ-law: 8, 16 kHz 64, 80, 96 kbit/s 16 bit 11.875 ms Yes Yes No No
If one desired to sample an FM radio broadcast centered at 87.9 MHz and bandlimited to a 200 kHz band, then an appropriate anti-alias filter would be centered on 87.9 MHz with 200 kHz bandwidth (or passband of 87.8 MHz to 88.0 MHz), and the sampling rate would be no less than 400 kHz, but should also satisfy other constraints to prevent aliasing.
AES67 also defines audio sample format and sample rate, supported number of channels, as well as IP data packet size and latency/buffering requirements. The standard calls out several protocol options for device discovery but does not require any to be implemented. Session Initiation Protocol is used for unicast connection management. No ...
Unless the sample rate is fixed by some outside constraint, selecting a suitable sample rate is an important design decision. A high rate will require more in terms of computational resources, but less in terms of anti-aliasing filters. Interference and beating with other signals in the system may also be an issue.