enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Step response - Wikipedia

    en.wikipedia.org/wiki/Step_response

    A typical step response for a second order system, illustrating overshoot, followed by ringing, all subsiding within a settling time. The step response of a system in a given initial state consists of the time evolution of its outputs when its control inputs are Heaviside step functions. In electronic engineering and control theory, step ...

  3. Settling time - Wikipedia

    en.wikipedia.org/wiki/Settling_time

    Settling time depends on the system response and natural frequency. The settling time for a second order , underdamped system responding to a step response can be approximated if the damping ratio ζ ≪ 1 {\displaystyle \zeta \ll 1} by T s = − ln ⁡ ( tolerance fraction ) damping ratio × natural freq {\displaystyle T_{s}=-{\frac {\ln ...

  4. Time constant - Wikipedia

    en.wikipedia.org/wiki/Time_constant

    First order LTI systems are characterized by the differential equation + = where τ represents the exponential decay constant and V is a function of time t = (). The right-hand side is the forcing function f(t) describing an external driving function of time, which can be regarded as the system input, to which V(t) is the response, or system output.

  5. Rise time - Wikipedia

    en.wikipedia.org/wiki/Rise_time

    For applications in control theory, according to Levine (1996, p. 158), rise time is defined as "the time required for the response to rise from x% to y% of its final value", with 0% to 100% rise time common for underdamped second order systems, 5% to 95% for critically damped and 10% to 90% for overdamped ones. [6]

  6. Overshoot (signal) - Wikipedia

    en.wikipedia.org/wiki/Overshoot_(signal)

    In the case of the unit step, the overshoot is just the maximum value of the step response minus one. Also see the definition of overshoot in an electronics context. For second-order systems, the percentage overshoot is a function of the damping ratio ζ and is given by [3]

  7. Transient response - Wikipedia

    en.wikipedia.org/wiki/Transient_response

    Typical second order transient system properties. Transient response can be quantified with the following properties. Rise time Rise time refers to the time required for a signal to change from a specified low value to a specified high value. Typically, these values are 10% and 90% of the step height.

  8. Damping - Wikipedia

    en.wikipedia.org/wiki/Damping

    The effect of varying damping ratio on a second-order system. The damping ratio is a parameter, usually denoted by ζ (Greek letter zeta), [7] that characterizes the frequency response of a second-order ordinary differential equation. It is particularly important in the study of control theory. It is also important in the harmonic oscillator ...

  9. Double integrator - Wikipedia

    en.wikipedia.org/wiki/Double_integrator

    Feedback system with a PD controller and a double integrator plant In systems and control theory , the double integrator is a canonical example of a second-order control system. [ 1 ] It models the dynamics of a simple mass in one-dimensional space under the effect of a time-varying force input u {\displaystyle {\textbf {u}}} .