Search results
Results from the WOW.Com Content Network
Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.
Linux supports Matrix RAID and Rapid Storage Technology (RST) through device mapper, with dmraid tool, for RAID 0, 1 and 10. And Linux MD RAID, with mdadm tool, for RAID 0, 1, 10, and 5. Set up of the RAID volumes must be done by using the ROM option in the Matrix Storage Manager, then further configuration can be done in DM-RAID or MD-RAID. [10]
geom_raid5 is a storage module created for the FreeBSD operating system. It facilitates RAID5 functionality without the need of a hardware RAID controller.. geom_raid5 allows storage of large amounts of data to be protected against disk failure, while providing good throughput performance.
As a RAID 0 array striped across RAID 5 elements, minimal RAID 50 configuration requires six drives. On the right is an example where three collections of 120 GB RAID 5s are striped together to make 720 GB of total storage space. One drive from each of the RAID 5 sets could fail without loss of data; for example, a RAID 50 configuration ...
RAID 1 – Mirror. RAID 4 – Like RAID 0, but with an extra device for the parity. RAID 5 – Like RAID 4, but with the parity distributed across all devices. RAID 6 – Like RAID 5, but with two parity segments per stripe. RAID 10 – Take a number of RAID 1 mirrorsets and stripe across them RAID 0 style.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
RAID 6 requires a minimum of four disks. As with RAID 5, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced. [11] With a RAID 6 array, using drives from multiple sources and manufacturers, it is possible to mitigate most of the problems associated with RAID 5.
Solaris Volume Manager (SVM; formerly known as Online: DiskSuite, and later Solstice DiskSuite) is a software package for creating, modifying and controlling RAID-0 (concatenation and stripe) volumes, RAID-1 (mirror) volumes, RAID 0+1 volumes, RAID 1+0 volumes, RAID-5 volumes, and soft partitions.