  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  3. Charles Dalziel - Wikipedia

    en.wikipedia.org/wiki/Charles_Dalziel

    He also invented the ground-fault circuit interrupter or GFCI in 1961. [1] The GFCI is commonly found in home bathrooms or kitchens. The device operates normally until 5 milliamps passes from the appliance to ground. Charles Dalziel was a pioneer in understanding electric shock in humans. Dalziel married Helen Bradford in 1931.

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A Siemens air circuit breaker rated for 1000 V and 2500 A continuous current mounted on a motor control cubicle. Medium-voltage circuit breakers rated between 1 and 72 kV may be assembled into metal-enclosed switchgear line-ups for indoor use or may be individual components installed outdoors in a substation.

  5. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    In addition, a fault condition to a bootleg ground will not trip a GFCI breaker, nor protect a receptacle that is wired from the load side of a GFCI receptacle. [2] Before 1996, in the United States it was common to ground the frames of large 120/240-volt permanently-connected appliances (such as a clothes dryer or oven) to neutral conductors.

  6. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  7. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    A safer and more reliable alternative identified in the US and Canadian electrical codes is to replace the outlet with a Ground Fault Circuit Interrupter (GFCI) breaker outlet. [3] Cheater plugs are also used to break ground loops in audio systems. [5] This practice has been condemned as disregarding electrical safety.