enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Boiling water reactor safety systems - Wikipedia

    en.wikipedia.org/wiki/Boiling_water_reactor...

    Examples of isolation groups include the main steamlines, the reactor water cleanup system, the reactor core isolation cooling (RCIC) system, shutdown cooling, and the residual heat removal system. For pipes which inject water into the containment, two safety-related check valves are generally used in lieu of motor operated valves.

  3. Boiling water reactor - Wikipedia

    en.wikipedia.org/wiki/Boiling_water_reactor

    Another example was the Isolation Condenser system, which relied on the principle of hot water/steam rising to bring hot coolant into large heat exchangers located above the reactor in very deep tanks of water, thus accomplishing residual heat removal. Yet another example was the omission of recirculation pumps within the core; these pumps were ...

  4. Advanced heavy-water reactor - Wikipedia

    en.wikipedia.org/wiki/Advanced_heavy-water_reactor

    Fuel is occupied by 452 lattice locations and the remaining 37 locations are occupied by shutdown system-1. This consists of 37 shut-off rods, 24 locations are for reactive control devices which are consisted of 8 absorber rods, 8 shim rods, and 8 regulating rods. By boiling light water at a pressure of 7 MPa, heat is then removed. The main ...

  5. Loss-of-coolant accident - Wikipedia

    en.wikipedia.org/wiki/Loss-of-coolant_accident

    The Fukushima Daiichi nuclear disaster in 2011 occurred due to a loss-of-coolant accident. The circuits that provided electrical power to the coolant pumps failed causing a loss-of-core-cooling that was critical for the removal of residual decay heat which is produced even after active reactors are shut down and nuclear fission has ceased.

  6. Loss-of-pressure-control accident - Wikipedia

    en.wikipedia.org/wiki/Loss-of-pressure-control...

    When pressure control is lost in a reactor plant, depending on the level of heat being generated by the reactor plant, the heat being removed by the steam or other auxiliary systems, the initial pressure, and the normal operating temperature of the plant, it could take minutes or even hours for operators to see significant trends in core behaviour.

  7. Nuclear reactor safety system - Wikipedia

    en.wikipedia.org/wiki/Nuclear_reactor_safety_system

    The essential service water system (ESWS) circulates the water that cools the plant's heat exchangers and other components before dissipating the heat into the environment. Because this includes cooling the systems that remove decay heat from both the primary system and the spent fuel rod cooling ponds, the ESWS is a safety-critical system. [7]

  8. Economic Simplified Boiling Water Reactor - Wikipedia

    en.wikipedia.org/wiki/Economic_Simplified...

    After the reactor has been depressurized, the decay heat is transferred to the containment as water inside the reactor boils and exits the reactor pressure vessel into the containment in the form of steam. The PCCS consists of a set of heat exchangers located in the upper portion of the reactor building.

  9. Fukushima nuclear accident (Unit 3 Reactor) - Wikipedia

    en.wikipedia.org/wiki/Fukushima_nuclear_accident...

    Following the reactor SCRAM, operators activated the reactor core isolation cooling system (RCIC) and the residual heat removal system and core spray systems were made available to cool the suppression pool; whether they were activated prior to the tsunami has not been made clear. The RHRS and CS pumps were knocked out of commission by the tsunami.