Pile integrity testing using low-strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. The test measures: pile length, or depth to anomalies; pile head stiffness; pile shaft mobility, which is dependent on pile section and concrete properties
Crosshole sonic logging (CSL) is a method to determine the structural integrity of drilled shafts and other concrete piles. The CSL method is considered to be more accurate than sonic echo testing in the determination of structural soundness of concrete within the drilled shaft inside of the rebar cage. This method provides little indication of ...
Dynamic load testing takes a further step in analyzing the data and computing static capacity and resistance distribution. Dynamic pile monitoring takes advantage of the fact that, for driven piles, it is possible to compute the energy delivered to the pile, compression stresses at the pile top and toe and tension stresses along the shaft.
Foundation integrity testing is the non-destructive testing of piled foundations.It was first used in the late 1960s, and has been developed over time by many companies. Three organizations supply a majority of the test equipment in use: CEBTP (Centre Expérimental de Recherches et d'Etudes du Bâtiment et des Travaux Publics) in Europe; Integrity Testing in Asia and Australia: and by GRL ...
Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...
A procedure for ultrasonic testing is outlined in ASTM C597 - 09. [9] In India, till 2018 ultrasonic testing was conducted according to IS 13311-1992.From 2018, procedure and specification for Ultrasonic pulse velocity test is outlined in IS 516 Part 5:Non destructive testing of concrete Section 1:Ultrasonic Pulse Velocity Testing. This test ...
The Statnamic load test is a type of test for assessing the load-carrying capacity of deep foundations which is faster and less expensive than the static load test.The Statnamic test was conceived in 1985, with the first prototype tests carried out in 1988 through collaboration between Berminghammer Foundation Equipment of Canada and TNO Building Research of the Netherlands.
When this concrete hardens it forms a sort of column that consolidates the surrounding soil. This process is repeated on all areas of the structure. The pile work technique consists of using piles, which, once inserted in the ground, support the foundation and the building above, by moving the loads or the weights towards soil layers that are ...