enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Impedance cardiography - Wikipedia

    en.wikipedia.org/wiki/Impedance_cardiography

    Impedance cardiography (ICG) is a non-invasive technology measuring total electrical conductivity of the thorax and its changes in time to process continuously a number of cardiodynamic parameters, such as stroke volume (SV), heart rate (HR), cardiac output (CO), ventricular ejection time (VET), pre-ejection period and used to detect the impedance changes caused by a high-frequency, low ...

  3. Impedance threshold device - Wikipedia

    en.wikipedia.org/wiki/Impedance_threshold_device

    An inspiratory impedance threshold device is a valve used in cardiopulmonary resuscitation (CPR) to decrease intrathoracic pressure and improve venous return to the heart. The valve is a part of a mask or other breathing device such as an endotracheal tube , and may open at high or low pressures (called "cracking pressures") [ citation needed ]

  4. Defibrillation - Wikipedia

    en.wikipedia.org/wiki/Defibrillation

    Defibrillation is a treatment for life-threatening cardiac arrhythmias, specifically ventricular fibrillation (V-Fib) and non-perfusing ventricular tachycardia (V-Tach). [1] [2] A defibrillator delivers a dose of electric current (often called a counter-shock) to the heart.

  5. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    Leads are broken down into three types: limb; augmented limb; and precordial or chest. The 12-lead ECG has a total of three limb leads and three augmented limb leads arranged like spokes of a wheel in the coronal plane (vertical), and six precordial leads or chest leads that lie on the perpendicular transverse plane (horizontal). [33]

  6. Implantable cardioverter-defibrillator - Wikipedia

    en.wikipedia.org/wiki/Implantable_cardioverter...

    A normal chest X-ray after placement of an ICD, showing the ICD generator in the upper left chest and the ICD lead in the right ventricle of the heart. Note the 2 opaque coils along the ICD lead. The process of implantation of an ICD system is similar to implantation of an artificial pacemaker. In fact, ICDs are composed of an ICD generator and ...

  7. Transcutaneous pacing - Wikipedia

    en.wikipedia.org/wiki/Transcutaneous_pacing

    The pads are then attached to a monitor/defibrillator, a heart rate is selected, and current (measured in milliamps) is increased until electrical capture (characterized by a wide QRS complex with tall, broad T wave on the ECG) is obtained, with a corresponding pulse. Pacing artifact on the ECG and severe muscle twitching may make this ...

  8. Cardiopulmonary resuscitation - Wikipedia

    en.wikipedia.org/wiki/Cardiopulmonary_resuscitation

    A defibrillator is a machine that produces a defibrillation: electric shocks that can restore the normal heart function of the victim. The common model of defibrillator out of an hospital is the automated external defibrillator (AED), a portable device that is especially easy to use because it produces recorded voice instructions.

  9. Pneumograph - Wikipedia

    en.wikipedia.org/wiki/Pneumograph

    There are various kinds of pneumographic devices, which have different principles of operation. In one mechanism, a flexible rubber vessel is attached to the chest. The vessel is equipped with sensors. Others are impedance based. In these methods, a high frequency (tens to hundreds of kHz) low amplitude current is injected across the chest cavity.