Heat flux can be determined using two surface temperature measurements on either side of the material using temperature sensors if k and x of the material are also known. Diagram depicting heat flux through a thermal insulation material with thermal conductivity, k, and thickness, x.
However, one needs to select if the heat flux is based on the pipe inner or the outer diameter. If the heat flux is based on the inner diameter of the pipe, and if the pipe wall is thin compared to this diameter, the curvature of the wall has a negligible effect on heat transfer. In this case, the pipe wall can be approximated as a flat plane ...
R-value is the temperature difference per unit of heat flux needed to sustain one unit of heat flux between the warmer surface and colder surface of a barrier under steady-state conditions. The measure is therefore equally relevant for lowering energy bills for heating in the winter, for cooling in the summer, and for general comfort.
The rate of heat flow is the amount of heat that is transferred per unit of time in some material, usually measured in watts (joules per second). Heat is the flow of thermal energy driven by thermal non-equilibrium, so the term 'heat flow' is a redundancy (i.e. a pleonasm ).
is the heat flux through the sample (W·m −2), is the temperature gradient (K·m −1) across the sample, is the cross-sectional area (m 2) perpendicular to the path of heat flow through the sample,
On-site heat flux measurements are often focused on testing the thermal transport properties of for example pipes, tanks, ovens and boilers, by calculating the heat flux q or the apparent thermal conductivity. The real-time energy gain or loss is measured under pseudo steady state-conditions with minimal disturbance by a heat flux transducer ...
These heat flux meters usually consist of thermopiles which provide an electrical signal which is in direct proportion to the heat flux. Typically they might be about 100 mm (3.9 in) in diameter and perhaps about 5 mm (0.20 in) thick and they need to be fixed firmly to the roof or wall which is under test in order to ensure good thermal contact.
The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...