enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Module:Convert/documentation/conversion data - Wikipedia

    en.wikipedia.org/wiki/Module:Convert/...

    The alttype field allows conversion between units of different type, provided each unit is whitelisted to allow the conversion. As at December 2013, the following energy units have alttype = "torque" (the first line consists of different units, while the second line consists of aliases for units in the first line):

  3. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The heat pump itself can be improved by increasing the size of the internal heat exchangers, which in turn increases the efficiency (and the cost) relative to the power of the compressor, and also by reducing the system's internal temperature gap over the compressor. Obviously, this latter measure makes some heat pumps unsuitable to produce ...

  4. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]

  5. Template:Convert/list of units/energy - Wikipedia

    en.wikipedia.org/wiki/Template:Convert/list_of...

    Energy; system unit code (alternative) symbol or abbrev. notes sample default conversion combinations SI: yottajoule: YJ YJ 1.0 YJ (2.8 × 10 17 kWh) zettajoule: ZJ ZJ 1.0 ZJ (2.8 × 10 14 kWh)

  6. Thermal efficiency - Wikipedia

    en.wikipedia.org/wiki/Thermal_efficiency

    So, for a boiler that produces 210 kW (or 700,000 BTU/h) output for each 300 kW (or 1,000,000 BTU/h) heat-equivalent input, its thermal efficiency is 210/300 = 0.70, or 70%. This means that 30% of the energy is lost to the environment. An electric resistance heater has a thermal efficiency close to 100%. [8]

  7. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    The overall heat transfer coefficient is a measure of the overall ability of a series of conductive and convective barriers to transfer heat. It is commonly applied to the calculation of heat transfer in heat exchangers , but can be applied equally well to other problems.

  8. Orders of magnitude (energy) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(energy)

    = 1 MW·h (megawatt-hour) 4.2×10 9 J: Energy released by explosion of 1 ton of TNT. 4.5×10 9 J: Average annual energy usage of a standard refrigerator [142] [143] 6.1×10 9 J: ≈ 1 bboe (barrel of oil equivalent) [144] 10 10 1.9×10 10 J: Kinetic energy of an Airbus A380 at cruising speed (560 tonnes at 511 knots or 263 m/s) 4.2×10 10 J

  9. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    For a water electrolysis unit operating at a constant temperature of 25 °C without the input of any additional heat energy, electrical energy would have to be supplied at a rate equivalent of the enthalpy (heat) of reaction or 285.830 kJ (0.07940 kWh) per gram mol of water consumed. [6] It would operate at a cell voltage of 1.48 V.