Search results
Results from the WOW.Com Content Network
The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.
Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]
The coefficient of performance, and the work required by a heat pump can be calculated easily by considering an ideal heat pump operating on the reversed Carnot cycle: If the low-temperature reservoir is at a temperature of 270 K (−3 °C) and the interior of the building is at 280 K (7 °C) the relevant coefficient of performance is 27.
The ionocaloric refrigeration cycle is an advanced cooling technology that utilizes the ionocaloric effect, driven by an electrochemical field, to achieve efficient and eco-friendly refrigeration. By manipulating the electrochemical potential through ion addition or removal, significant temperature changes and entropy variations are achieved.
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
A refrigeration cycle describes the changes that take place in the refrigerant as it alternately absorbs and ... A refrigeration system's coefficient of performance ...
The performance of the absorption heat pump is indicated by the coefficient of performance (COP). The COP is the ratio of the removed (for refrigeration) or provided (for heating) heat to the energy input. At present, the maximum temperature of its output does not exceed 150 °C. The temperature rise ΔT is generally 30–50 °C.
The most common refrigeration cycle is the vapor compression cycle, which models systems using refrigerants that change phase. The absorption refrigeration cycle is an alternative that absorbs the refrigerant in a liquid solution rather than evaporating it. Gas refrigeration cycles include the reversed Brayton cycle and the Hampson–Linde cycle.