enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Leeb rebound hardness test - Wikipedia

    en.wikipedia.org/wiki/Leeb_rebound_hardness_test

    A test takes a mere 2 seconds and, using the standard probe D, leaves an indentation of just ~0.5 mm in diameter on steel or steel casting with a Leeb hardness of 600 HLD. By comparison, a Brinell indentation on the same material is ~3 mm (hardness value ~400 HBW 10/3000), with a standard-compliant measuring time of ~15 seconds plus the time ...

  3. Chemotaxis assay - Wikipedia

    en.wikipedia.org/wiki/Chemotaxis_assay

    Some capillary techniques provide also a chamber like arrangement, however, there is no filter between the cells and the test substance. [5] Quantitative results are gained by the multiwell type of this probe using 4-8-12-channel pipettes. Accuracy of the pipette and increased number of the parallel running samples is the great advantage of ...

  4. Fluorescence recovery after photobleaching - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_recovery...

    This will be true, for example, if a cylindrical volume is bleached with the axis of the cylinder along the z axis and with this cylindrical volume going through the entire height of the cell. Then diffusion along the z axis does not cause fluorescence recovery as all protein is bleached uniformly along the z axis, and so neglecting it, as ...

  5. Geotechnical investigation - Wikipedia

    en.wikipedia.org/wiki/Geotechnical_investigation

    A soil sample recovered from a test boring using a split spoon sampler. Borings come in two main varieties: large diameter and small diameter. Large-diameter borings are rarely used because of safety concerns and expense but are sometimes used to allow a geologist or an engineer to visually and manually examine the soil and rock stratigraphy in-situ.

  6. Pump–probe microscopy - Wikipedia

    en.wikipedia.org/wiki/Pump–probe_microscopy

    Pump–probe microscopy is a non-linear optical imaging modality used in femtochemistry to study chemical reactions. It generates high-contrast images from endogenous non-fluorescent targets. It generates high-contrast images from endogenous non-fluorescent targets.

  7. Test probe - Wikipedia

    en.wikipedia.org/wiki/Test_probe

    A test probe is a physical device used to connect electronic test equipment to a device under test (DUT). Test probes range from very simple, robust devices to complex probes that are sophisticated, expensive, and fragile. Specific types include test prods, oscilloscope probes and current probes. A test probe is often supplied as a test lead ...

  8. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...

  9. Angle-resolved photoemission spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Angle-resolved...

    To take maps over energy and two-dimensional momentum space, either the sample is rotated in the proper direction so that the slit receives electrons from adjacent emission angles, or the electron plume is steered inside the electrostatic lens with the sample fixed. The slit width will determine the step size of the angular scans.