enow.com Web Search

  1. Ads

    related to: 3 pole 30 amp disconnect non fused circuit

Search results

  1. Results from the WOW.Com Content Network
  2. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    The fuse element, or "fuse link", is the replaceable portion of the assembly that melts and breaks the circuit when the electric current through it exceeds its rated current value. There are many types of fuse elements for many different uses such as a type T fuse also known as a "slow-blow fuse" being used for sidelines.

  3. Ring circuit - Wikipedia

    en.wikipedia.org/wiki/Ring_circuit

    The IET Wiring Regulations permit an unlimited number of 13A socket outlets (at any point unfused single or double, or any number fused) to be installed on a ring circuit, provided that the floor area served does not exceed 100 m 2. In practice, most small and medium houses have one ring circuit per storey, with larger premises having more.

  4. Disconnector - Wikipedia

    en.wikipedia.org/wiki/Disconnector

    In electrical engineering, a disconnector, disconnect switch or isolator switch is a type of switching device with visible contacts, used to ensure that an electrical circuit is completely de-energized for service or maintenance.

  5. Via (electronics) - Wikipedia

    en.wikipedia.org/wiki/Via_(electronics)

    (3) Buried via. The gray and green layers are nonconducting, while the thin orange layers and red vias are conductive. A via (Latin, 'path' or 'way') is an electrical connection between two or more metal layers of a printed circuit boards (PCB) or integrated circuit. Essentially a via is a small drilled hole that goes through two or more ...

  6. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Under short-circuit conditions, the calculated or measured maximum prospective short-circuit current may be many times the normal, rated current of the circuit. When electrical contacts open to interrupt a large current, there is a tendency for an arc to form between the opened contacts, which would allow the current to continue.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    A dual-element fuse may contain a metal strip that melts instantly on a short circuit, and also contain a low-melting solder joint that responds to long-term overload of low values compared to a short circuit. Fuse elements may be supported by steel or nichrome wires, so that no strain is placed on the element, but a spring may be included to ...

  9. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-wire three-phase circuit is usually more economical than an equivalent two-wire single-phase circuit at the same line-to-ground voltage because it uses less conductor material to transmit a given amount of electrical power. [3] Three-phase power is mainly used directly to power large induction motors, other electric motors and other ...

  1. Ads

    related to: 3 pole 30 amp disconnect non fused circuit