Bromochlorodifluoromethane (BCF), also referred to by the code numbers Halon 1211 and Freon 12B1, is a haloalkane with the chemical formula C F 2 Cl Br.It is used for fire suppression, especially for expensive equipment or items that could be damaged by the residue from other types of extinguishers. [1]
Fire extinguisher. A stored-pressure fire extinguisher. A fire extinguisher is a handheld active fire protection device usually filled with a dry or wet chemical used to extinguish or control small fires, often in emergencies. It is not intended for use on an out-of-control fire, such as one which has reached the ceiling, endangers the user (i ...
Halon 1301 is widely used by the U.S. Military [7] and NASA in a 2-3/4 lb portable extinguisher with a sealed, disposable cylinder for quick recharging. Other agents such as CO 2 and FE-36 (HFC-236fa) wet chemical are largely replacing halon 1301 for environmental concerns. Civilian models in 2-3/4, 3, and 4 lb sizes were also made.
Bromochloromethane or methylene bromochloride and Halon 1011 is a mixed halomethane. It is a heavy low-viscosity liquid with refractive index 1.4808. Halon 1011 was invented for use in fire extinguishers in Germany during the mid-1940s, in an attempt to create a less toxic, more effective alternative to carbon tetrachloride .
Halotron I. Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa). Halotron I is a fire extinguishing agent based on the raw material HCFC-123 (93%) mixed with tetrafluoromethane and argon as propellants.
[citation needed]) Halon 1211 also has low toxicity, although it is more toxic than Halon 1301, and thus considered unsuitable for flooding systems. However, Halon 1301 fire suppression is not completely non-toxic; very high temperature flame, or contact with red-hot metal, can cause decomposition of Halon 1301 to toxic byproducts.