Search results
Results from the WOW.Com Content Network
A Wheatstone bridge is an electrical circuit used to measure an unknown electrical resistance by balancing two legs of a bridge circuit, one leg of which includes the unknown component. The primary benefit of the circuit is its ability to provide extremely accurate measurements (in contrast with something like a simple voltage divider ). [ 1 ]
An unmounted resistive foil strain gauge. A strain gauge takes advantage of the physical property of electrical conductance and its dependence on the conductor's geometry. . When an electrical conductor is stretched within the limits of its elasticity such that it does not break or permanently deform, it will become narrower and longer, which increases its electrical resistance end-to-
Since the change in resistance measured by a single strain gauge is extremely small, it is difficult to accurately measure changes. Increasing the number of strain gauges applied collectively magnifies these small changes into something more measurable. A set of 4 strain gauges set in a specific circuit is an application of a Wheatstone bridge.
English: Diaphragm strain gauge for pressure transducers. The two outer gauges measure radial strain, the two inner ones measure tangential strain. Not all internal connections for the Wheatstone bridge have already been made, so that resistors for calibration and temperature compensation can be added.
A Wheatstone Bridge Circuit for Measuring Resistance: Date: 22 May 2006: Source: Own Work, based on a standard circuit diagram: Author: jjbeard: Permission (Reusing ...
The best-known bridge circuit, the Wheatstone bridge, was invented by Samuel Hunter Christie and popularized by Charles Wheatstone, and is used for measuring resistance. It is constructed from four resistors, two of known values R 1 and R 3 (see diagram), one whose resistance is to be determined R x, and one which is variable and calibrated R 2.
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.
A standard Wheatstone bridge for comparison. Points A, B, C and D in both circuit diagrams correspond. X and Y correspond to R 1 and R 2, P and Q correspond to R 3 and R X. Note that with the Carey Foster bridge, we are measuring R 1 rather than R X. Let ℓ 1 be the null point D on the bridge wire EF in percent.