Search results

  1. Results from the WOW.Com Content Network
  2. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    The arrangement of switches, circuit breakers, and buses used affects the cost and reliability of the substation. For important substations a ring bus, double bus, or so-called "breaker and a half" setup can be used, so that the failure of any one circuit breaker does not interrupt power to other circuits, and so that parts of the substation ...

  3. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current. Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [5]

  4. Intelligent electronic device - Wikipedia

    en.wikipedia.org/wiki/Intelligent_electronic_device

    Most IEDs have a communication port and built-in support for standard communication protocols (DNP3, IEC104 or IEC61850), so they can communicate directly with the SCADA system or a substation programmable logic controller. Alternatively, they can be connected to a substation RTU that acts as a gateway towards the SCADA server.

  5. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Circuit breakers and switches enable the substation to be disconnected from the transmission grid or for distribution lines to be disconnected. Transformers step down transmission voltages, 35 kV or more, down to primary distribution voltages. These are medium voltage circuits, usually 600–35 000 V. [1]

  6. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A small circuit breaker typically has a manual control lever to switch the circuit off or reset a tripped breaker, while a larger unit may use a solenoid to trip the mechanism, and an electric motor to restore energy to springs (which rapidly separate contacts when the breaker is tripped).

  7. Selectivity (circuit breakers) - Wikipedia

    en.wikipedia.org/wiki/Selectivity_(circuit_breakers)

    The purpose of selectivity is to minimize the impact of a failure on the network. Faults in an installation are, for example, overload and short circuit. [1] [2] There are four ways in which selectivity is achieved: [3] Current selectivity: different breaking capacities; Time selectivity: time delay before tripping of a breaker

  8. Sulfur hexafluoride circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Sulfur_hexafluoride...

    Sulfur hexafluoride circuit breakers protect electrical power stations and distribution systems by interrupting electric currents, when tripped by a protective relay. Instead of oil, air, or a vacuum, a sulfur hexafluoride circuit breaker uses sulfur hexafluoride (SF 6) gas to cool and quench the arc on opening a circuit. Advantages over other ...

  9. Switchgear - Wikipedia

    en.wikipedia.org/wiki/Switchgear

    High-voltage switchgear A section of a large switchgear panel. Tram switchgear This circuit breaker uses both SF 6 and air as insulation.. In an electric power system, a switchgear is composed of electrical disconnect switches, fuses or circuit breakers used to control, protect and isolate electrical equipment.