enow.com Web Search

  1. Ad

    related to: c arm fluoroscopy procedures

Search results

  1. Results from the WOW.Com Content Network
  2. Fluoroscopy - Wikipedia

    en.wikipedia.org/wiki/Fluoroscopy

    The problem of radiation injuries due to fluoroscopy has been further addressed in review articles in 2000 [61] and 2010. [62] While deterministic radiation effects are a possibility, radiation burns are not typical in standard fluoroscopic procedures. Most procedures sufficiently long in duration to produce radiation burns are part of ...

  3. X-ray image intensifier - Wikipedia

    en.wikipedia.org/wiki/X-ray_image_intensifier

    A mobile fluoroscopy unit generally consists of two units, the X-ray generator and image detector (II) on a moveable C-arm, and a separate workstation unit used to store and manipulate the images. [13] The patient is positioned between the two arms, typically on a radiolucent bed. Fixed systems may have a c-arm mounted to a ceiling gantry, with ...

  4. Cone beam computed tomography - Wikipedia

    en.wikipedia.org/wiki/Cone_beam_computed_tomography

    [10] [11] Many fixed, and even mobile, C-arm fluoroscopy systems are now capable of CBCT acquisitions, in addition to traditional planar fluoroscopy. [12] [13] CBCT aids image guidance during interventional radiology procedures treating various medical conditions including knee osteoarthritis, benign prostatic hyperplasia, and hepatocellular ...

  5. Hybrid operating room - Wikipedia

    en.wikipedia.org/wiki/Hybrid_operating_room

    A good fluoroscopic view is essential, whereby an exact perpendicular angle to the aortic root is considered to be optimal for the implantation. Recently, applications have been released which support the surgeon in selecting this optimal fluoroscopy angulation or even drive the C-arm automatically into the perpendicular view to the aortic root.

  6. G-arm medical imaging - Wikipedia

    en.wikipedia.org/wiki/G-arm_medical_imaging

    G-arm medical imaging systems are based on fluoroscopic X-ray and are used for a variety of diagnostic imaging and minimally invasive surgical procedures.The name is derived from the G-shaped arm used to connect two X-ray generators and two X-ray detectors, image intensifiers or digital flat panel detectors, to one another.

  7. Rotational angiography - Wikipedia

    en.wikipedia.org/wiki/Rotational_angiography

    Rotational angiography is a medical imaging technique based on x-ray, that allows to acquire CT-like 3D volumes during hybrid surgery or during a catheter intervention using a fixed C-Arm. The fixed C-Arm thereby rotates around the patient and acquires a series of x-ray images that are then reconstructed through software algorithms into a 3D ...

  8. Fluorescence image-guided surgery - Wikipedia

    en.wikipedia.org/wiki/Fluorescence_image-guided...

    A stand or arm can be used to maintain the system on top of the operating field, particularly when the weight and complexity of the device is high (e.g. when multiple cameras are used). The main disadvantage of such devices is that operating theater lights can interfere with the fluorescence emission channel, with a consequent decrease of ...

  9. Interventional radiology - Wikipedia

    en.wikipedia.org/wiki/Interventional_radiology

    Interventional radiology (IR) is a medical specialty that performs various minimally-invasive procedures using medical imaging guidance, such as x-ray fluoroscopy, computed tomography, magnetic resonance imaging, or ultrasound.

  1. Ad

    related to: c arm fluoroscopy procedures