enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Boiler blowdown - Wikipedia

    en.wikipedia.org/wiki/Boiler_blowdown

    Several short blowdown events remove sludge more effectively than a single continuous blowdown. Shorter blowdown events cause less significant changes in boiler water level, and are safer during periods of high steam demand. [5] Bottom blowdown piping drains the lowest parts of the boiler so it can be used to drain the boiler for servicing.

  3. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    Though the total particulate emissions from wet cooling towers with fresh water make-up is much less, they contain more PM 10 and PM 2.5 than the total emissions from wet cooling towers with sea water make-up. This is due to lesser salt content in fresh water drift (below 2,000 ppm) compared to the salt content of sea water drift (60,000 ppm).

  4. Blowdown stack - Wikipedia

    en.wikipedia.org/wiki/Blowdown_stack

    Blowdown is the controlled removal, safe flow and disposal of vapour from a pressure vessel. [1] Blowdown, or depressurisation, removes hazardous inventory from a vessel, reduces the pressure in the vessel and thereby reduces the stresses in the vessel walls. Blowdown is used prior to draining of a vessel for maintenance.

  5. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    HVAC (Heating, Ventilation and Air Conditioning) equipment needs a control system to regulate the operation of a heating and/or air conditioning system. [1] Usually a sensing device is used to compare the actual state (e.g. temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g. start the ...

  6. Shutdown valve - Wikipedia

    en.wikipedia.org/wiki/Shutdown_valve

    A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.

  7. Steam and water analysis system - Wikipedia

    en.wikipedia.org/wiki/Steam_and_water_analysis...

    This can be achieved by two-stage cooling. In the first stage cooling (also known as 'primary cooling'), the sample is cooled by using available cooling water. In most of the countries, cooling water is available in the range of 30–32 °C. This cooling water can cool the sample unto 35 °C(considering an approach temperature of 3 to 5 °C).

  8. Blowout preventer - Wikipedia

    en.wikipedia.org/wiki/Blowout_preventer

    A blowout preventer (BOP) (pronounced B-O-P) [1] is a specialized valve or similar mechanical device, used to seal, control and monitor oil and gas wells to prevent blowouts, the uncontrolled release of crude oil or natural gas from a well. They are usually installed in stacks of other valves.

  9. Level control valve - Wikipedia

    en.wikipedia.org/wiki/Level_control_valve

    A level control valve or altitude control valve is a type of valve that automatically responds to changes in the height of a liquid in some storage system. A common example is the set of ballcocks in a flush toilet , where each stage of the flush cycle is actuated by the emptying or filling of the tank.