enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Dehumidifier - Wikipedia

    en.wikipedia.org/wiki/Dehumidifier

    If the condensate from the cooling coils is drained away from the room as it drips off the cooling coils, the result will be room air that is drier but slightly warmer. However, many window air conditioners are designed to dispose of condensate water by re-evaporating it into the exhaust air stream, which cancels out the air humidity decrease ...

  3. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    The fan coil unit will contain a purpose designed drip tray with drain connection for this purpose. The simplest means to drain the condensate from multiple fan coil units will be by a network of pipework laid to falls to a suitable point. Alternatively a condensate pump may be employed where space for such gravity pipework is limited.

  4. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Supply diffusers in the ceiling are fed by fan coil units in the ceiling void or by air handling units in a remote plant room. The fan coil or handling unit takes in return air from the ceiling void and mix this with fresh air and cool, or heat it, as required to achieve the room design conditions. This arrangement is known as 'conventional ...

  5. Air handler - Wikipedia

    en.wikipedia.org/wiki/Air_handler

    Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units. A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit ( MAU ) or fresh air handling unit ( FAHU ).

  6. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    This stage may switch off the HVAC equipment (preventing the production of further condensate), trigger an alarm, or both. Some systems may include two pumps to empty the tank. In this case, the two pumps often alternate operation, and a two-stage switch serves to energize the on-duty pump at the first stage and then energize the remaining pump ...

  7. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  8. Heater core - Wikipedia

    en.wikipedia.org/wiki/Heater_core

    The internal combustion engine in most cars and trucks is cooled by a water and antifreeze mixture that is circulated through the engine and radiator by a water pump to enable the radiator to give off engine heat to the atmosphere. Some of that coolant can be diverted through the heater core to give some engine heat to the cabin, or adjust the ...

  9. Variable air volume - Wikipedia

    en.wikipedia.org/wiki/Variable_air_volume

    A CAV box can only operate between a constant, maximum value, or an “off” state. [5] This difference means the VAV box can provide tighter space temperature control while using much less energy. Another reason why VAV boxes save more energy is that they are coupled with variable-speed drives on fans , so the fans can ramp down when the VAV ...