A wire break in the fault to load section, or in the earth to ground section, will disable operation of the ELCB. Requirement of an additional third wire from the load to the ELCB. Separate devices cannot be grounded individually. Any additional connection to Earth on the protected system can disable the detector.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.
An insulation monitoring device monitors the ungrounded system between an active phase conductor and earth.It is intended to give an alert (light and sound) or disconnect the power supply when the resistance between the two conductors drops below a set value, usually 50 kΩ (sample of IEC standard for medical applications).
This detection of small leakage currents (less than 1 ampere) on a medium voltage line can indicate insulator failure, broken cables or lines coming into contact with trees. There is no merit in applying reclosing to this scenario, and the industry best practice is not to reclose on sensitive earth fault.
Since the earth leakage is restricted, leakage protection devices can be set to less than 750 mA. By comparison, in a solidly earthed system, earth fault current can be as much as the available short-circuit current. The neutral earthing resistor is monitored to detect an interrupted ground connection and to shut off power if a fault is detected.
Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.
The diagram shows leakage current from an appliance such as an electric motor A flowing through the building's ground system G to the neutral wire at the utility ground bonding point at the service panel. The ground loop between components C1 and C2 creates a second parallel path for the current. [8]
A complex mathematical algorithm analyzes data from pressure sensors and is able in a matter of seconds to point to the location of the leakage with accuracy less than 50 m (164 ft). Experimental data has shown the method's ability to detect leaks less than 3mm (0.1 inch) in diameter and operate with the lowest false alarm rate in the industry ...