enow.com Web Search

  1. Ads

    related to: calibration solution for ph tester reviews complaints company

Search results

  1. Results from the WOW.Com Content Network
  2. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    Beckman Model M pH Meter, 1937 [1] Beckman model 72 pH meter, 1960 781 pH/Ion Meter pH meter by Metrohm. A pH meter is a scientific instrument that measures the hydrogen-ion activity in water-based solutions, indicating its acidity or alkalinity expressed as pH. [2]

  3. Standard solution - Wikipedia

    en.wikipedia.org/wiki/Standard_solution

    Standard solutions are commonly used to determine the concentration of an analyte species via calibration curve. A calibration curve is obtained by measuring a series of standard solutions with known concentrations, which can be used to determine the concentration of an unknown sample using linear regression analysis. [10]

  4. Certified reference materials - Wikipedia

    en.wikipedia.org/wiki/Certified_reference_materials

    [21]: 119–124 For example, stabilizing agents such as antioxidants or antimicrobial agents may be added to prevent degradation, liquids containing certified concentrations of trace metals may have pH adjusted to keep metals in solution, and clinical reference materials may be freeze-dried for long term storage if they can be reconstituted ...

  5. Internal standard - Wikipedia

    en.wikipedia.org/wiki/Internal_standard

    The calibration curve on the bottom does use the internal standard method. One way to visualize the internal standard method is to create one calibration curve that doesn't use the method and one calibration curve that does. Suppose there are known concentrations of nickel in a set of calibration solutions: 0 ppm, 1.6 ppm, 3.2 ppm, 4.8 ppm, 6.4 ...

  6. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.

  7. Analytical chemistry - Wikipedia

    en.wikipedia.org/wiki/Analytical_chemistry

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL) A general method for analysis of concentration involves the creation of a calibration curve. This allows for the determination of the amount of a chemical in a material by comparing the results of an unknown ...

  1. Ads

    related to: calibration solution for ph tester reviews complaints company