Search results
Results from the WOW.Com Content Network
Overflow rate is often used for flow over an edge (for example a weir) in the unit m 3 /h per m. The unit of overflow rate is usually meters (or feet) per second, a velocity. Any particle with settling velocity (v s) greater than the overflow rate will settle out, while other particles will settle in the ratio v s /v o. There are ...
The rectifying section operating line for the section above the inlet feed stream of the distillation column (shown in green in Figure 1) starts at the intersection of the distillate composition line and the x = y line and continues at a downward slope of L / (D + L), where L is the molar flow rate of reflux and D is the molar flow rate of the ...
Chute spillways carry supercritical flow through the steep slope of an open channel. There are four main components of a chute spillway: [1] The elements of a spillway are the inlet, the vertical curve section (ogee curve), the steep-sloped channel and the outlet.
Water can be added intermittently to the bucket, which leaks out at a constant rate until empty, and will also overflow when full. The leaky bucket is an algorithm based on an analogy of how a bucket with a constant leak will overflow if either the average rate at which water is poured in exceeds the rate at which the bucket leaks or if more ...
The rate of discharge is controlled only by the height of water above the reservoir's spillway. The fraction of storage volume in the reservoir above the spillway crest can only be used for the temporary storage of floodwater; it cannot be used as water supply storage because it sits higher than the dam can retain it.
The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .
The equation for head loss in pipes, also referred to as slope, S, expressed in "feet per foot of length" vs. in 'psi per foot of length' as described above, with the inside pipe diameter, d, being entered in feet vs. inches, and the flow rate, Q, being entered in cubic feet per second, cfs, vs. gallons per minute, gpm, appears very similar.
Mass flow rate is defined by the limit [3] [4] ˙ = =, i.e., the flow of mass m through a surface per unit time t. The overdot on the m is Newton's notation for a time derivative . Since mass is a scalar quantity, the mass flow rate (the time derivative of mass) is also a scalar quantity.