A major application of current loops is the industry de facto standard 4–20 mA current loop for process control applications, where they are extensively used to carry signals from process instrumentation to proportional–integral–derivative (PID) controllers, supervisory control and data acquisition (SCADA) systems, and programmable logic ...
A digital current loop uses the absence of current for high (space or break), and the presence of current in the loop for low (mark). [1] This is done to ensure that on normal conditions there is always current flowing and in the event of a line being cut the flow stops indefinitely, immediately raising the alarm of the event usually as the heavy noise of the teleprinter not being synchronized ...
The HART Communication Protocol (Highway Addressable Remote Transducer) is a hybrid analog+digital industrial automation open protocol. Its most notable advantage is that it can communicate over legacy 4–20 mA analog instrumentation current loops, sharing the pair of wires used by the analog-only host systems.
The processors receive information from input modules, process the information and decide control actions to be signalled by the output modules. The field inputs and outputs can be analog signals e.g. 4–20 mA DC current loop or two-state signals that switch either "on" or "off", such as relay contacts or a semiconductor switch.
Current mode logic (CML), or source-coupled logic (SCL), is a digital design style used both for logic gates and for board-level digital signaling of digital data. The basic principle of CML is that current from a constant current generator is steered between two alternate paths depending on whether a logic zero or logic one is being represented.
A programmable logic controller (PLC) or programmable controller is an industrial computer that has been ruggedized and adapted for the control of manufacturing processes, such as assembly lines, machines, robotic devices, or any activity that requires high reliability, ease of programming, and process fault diagnosis.
Example of a continuous flow control loop. Signalling is by industry standard 4-20 mA current loops, and a "smart" valve positioner ensures the control valve operates correctly. The fundamental building block of any industrial control system is the control loop, which controls just one process variable.
A pair of parallel conductors with current Î 1 and Î 2 flowing on each conductor, which can be decomposed into CM and DM current respectively. Fig. 1. CM and DM Current Illustration on Pair Conductors. As shown in the figure above, the relations between Î 1, Î 2 and modal current are given: Î 1 = Î C + Î D Î 2 = Î C - Î D