Attenuation is linearly dependent on the medium length and attenuation coefficient, as well as – approximately – the frequency of the incident ultrasound beam for biological tissue (while for simpler media, such as air, the relationship is quadratic). Attenuation coefficients vary widely for different media.
Ultrasound attenuation spectroscopy is a method for characterizing properties of fluids and dispersed particles. It is also known as acoustic spectroscopy. There is an international standard for this method. [1] [2] Measurement of attenuation coefficient versus ultrasound frequency yields
The attenuation coefficient of a volume, denoted μ, is defined as [6] =, where Φ e is the radiant flux;; z is the path length of the beam.; Note that for an attenuation coefficient which does not vary with z, this equation is solved along a line from =0 to as:
In acoustics, Stokes's law of sound attenuation is a formula for the attenuation of sound in a Newtonian fluid, such as water or air, due to the fluid's viscosity.It states that the amplitude of a plane wave decreases exponentially with distance traveled, at a rate α given by = where η is the dynamic viscosity coefficient of the fluid, ω is the sound's angular frequency, ρ is the fluid ...
This concepts of ultrasonic proving can be used to inversely resolve the grain size in the time domain when the scattering attenuation coefficient is measured from testing data, providing the non-destructive way to predict material's property with rather simple instruments.
Unlike X-ray or other physical properties which provide typically only one information, ultrasound provides multiple information of the object for imaging: the attenuation the wave's sound pressure experiences indicate on the object's attenuation coefficient, the time-of-flight of the wave gives speed of sound information, and the scattered ...
f c is the center frequency of the ultrasound pulse . MI is measured with a calibrated hydrophone in a tank of degassed water. The pulse pressure amplitudes are measured along the central axis of the ultrasound beam. The P r is calculated by reducing it using an attenuation coefficient of 0.3 dB/cm/MHz. [2]
The figure provided in [30] provides an estimation of the attenuation that the ultrasound would suffer as it propagated through air. The figures from this graph correspond to completely linear propagation, and the exact effect of the nonlinear demodulation phenomena on the attenuation of the ultrasonic carrier waves in air was not considered.