The attenuation coefficient of a volume, denoted μ, is defined as [6] =, where Φ e is the radiant flux;; z is the path length of the beam.; Note that for an attenuation coefficient which does not vary with z, this equation is solved along a line from =0 to as:
Ultrasound attenuation spectroscopy is a method for characterizing properties of fluids and dispersed particles. It is also known as acoustic spectroscopy. There is an international standard for this method. [1] [2] Measurement of attenuation coefficient versus ultrasound frequency yields
Attenuation coefficients are used to quantify different media according to how strongly the transmitted ultrasound amplitude decreases as a function of frequency. The attenuation coefficient ( α {\displaystyle \alpha } ) can be used to determine total attenuation in dB in the medium using the following formula:
The transducer is typically separated from the test object by a couplant [4] such as a gel, oil or water, [1] as in immersion testing. However, when ultrasonic testing is conducted with an Electromagnetic Acoustic Transducer (EMAT) the use of couplant is not required. There are two methods of receiving the ultrasound waveform: reflection and ...
Unlike X-ray or other physical properties which provide typically only one information, ultrasound provides multiple information of the object for imaging: the attenuation the wave's sound pressure experiences indicate on the object's attenuation coefficient, the time-of-flight of the wave gives speed of sound information, and the scattered ...
absorption coefficient is essentially (but not quite always) synonymous with attenuation coefficient; see attenuation coefficient for details; molar absorption coefficient or molar extinction coefficient , also called molar absorptivity , is the attenuation coefficient divided by molarity (and usually multiplied by ln(10), i.e., decadic); see ...
Ultrasound transmission tomography (UTT) is a form of tomography involving ultrasound. [1]Like X-ray tomography, the attenuation of the ultrasound as it passes through the object can be measured, but since the speed of sound is so much lower than the speed of light, the delay as it passes through the object can also be measured, allowing estimation of both the attenuation coefficient and the ...
f c is the center frequency of the ultrasound pulse . MI is measured with a calibrated hydrophone in a tank of degassed water. The pulse pressure amplitudes are measured along the central axis of the ultrasound beam. The P r is calculated by reducing it using an attenuation coefficient of 0.3 dB/cm/MHz. [2]