  1. Results from the WOW.Com Content Network
  2. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature. This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed.

  3. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    A fire alarm control panel Fire alarm speaker and pull station. Fire alarm systems are composed of several distinct parts: Fire alarm control panel (FACP), or fire alarm control unit (FACU): This component, the hub of the system, monitors inputs and system integrity, controls outputs, and transmits information.

  4. Linear heat detection - Wikipedia

    en.wikipedia.org/wiki/Linear_Heat_Detection

    Linear heat detection (LHD) (also known as linear detection wire or linear heat detection cable or linear heat) is a very commonly used method of fire detection. It can detect a fire anywhere along the length of the cable, and can be of lengths in excess of a kilometer. Applications can range from building fire alarm systems to mobile plant ...

  5. Manual fire alarm activation - Wikipedia

    en.wikipedia.org/wiki/Manual_fire_alarm_activation

    A fire alarm pull station is an active fire protection device, usually wall-mounted, that, when activated, initiates an alarm on a fire alarm system. This is the most common design in North America. This is the most common design in North America.

  6. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...

  7. Two-alarm fire tears through NYC building as 10 rushed to ...

    www.aol.com/fire-tears-nyc-building-10-160944678...

    A raging two-alarm fire left 15 people injured in an Upper Manhattan apartment building Tuesday morning, reports say. The blaze tore through the first floor of a six-story building West 204th ...

  8. Annunciator panel - Wikipedia

    en.wikipedia.org/wiki/Annunciator_panel

    A fire alarm annunciator panel is located where it is accessible to fire-fighting crews, such as at building entrances/exits. The annunciator panel will indicate the system status using lamps (or LEDs), an audible warning tone, and depending on the system technology, the exact location or approximate physical location of the source of a fire ...