A mass flow controller is designed and calibrated to control a specific type of liquid or gas at a particular range of flow rates. The MFC can be given a setpoint from 0 to 100% of its full scale range but is typically operated in the 10 to 90% of full scale where the best accuracy is achieved.
The mass flow rate is the mass of the fluid traveling past a fixed point per unit time. The mass flow meter does not measure the volume per unit time (e.g. cubic meters per second) passing through the device; it measures the mass per unit time (e.g. kilograms per second) flowing through the device. Volumetric flow rate is the mass flow rate ...
Ultrasonic flow meter; Mass flow meter (Coriolis force). Flow measurement methods other than positive-displacement flowmeters rely on forces produced by the flowing stream as it overcomes a known constriction, to indirectly calculate flow. Flow may be measured by measuring the velocity of fluid over a known area.
It was awarded the Flow Control Innovations Award in 2011. [2] Sage Metering was the first thermal flow meter manufacturer to provide a unique and easy to invoke on-site calibration verification. [3] (This saves time and money since the user does not have to remove the meter and return it to the factory (or a third party) for annual flow meter ...
Many mass flow controllers (MFC) which combine a mass flow meter, electronics and a valve are based on this design. Furthermore, a thermal mass flow meter can be built by measuring temperature differential across a silicon-based MEMS chip. Both types measure fluid mass flow rate by means of the heat convected from a heated surface to the ...
Custody transfer of liquid flow measurement follow guidelines set by the ISO. By industrial consensus, liquid flow measurement is defined as having an overall uncertainty of ±0.25% or better. The overall uncertainty is derived from an appropriate statistical combination of the component uncertainties in the measurement system.
The thermodynamic method is used for performance testing of pumps, flow meter calibration, system curve tests, and other applications. It is capable of achieving results with uncertainties of less than 1% in pump efficiency and less than 1.5% in flow [ 3 ] while being able to test piping configurations where other conventional pump testing ...
MFI Measuring device. The Melt Flow Index (MFI) is a measure of the ease of flow of the melt of a thermoplastic polymer.It is defined as the mass of polymer, in grams, flowing in ten minutes through a capillary of a specific diameter and length by a pressure applied via prescribed alternative gravimetric weights for alternative prescribed temperatures.