enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Molar absorption coefficient - Wikipedia

    en.wikipedia.org/wiki/Molar_absorption_coefficient

    c is the molar concentration of those species; ℓ is the path length. Different disciplines have different conventions as to whether absorbance is decadic (10-based) or Napierian (e-based), i.e., defined with respect to the transmission via common logarithm (log 10) or a natural logarithm (ln). The molar absorption coefficient is usually decadic.

  3. Variable pathlength cell - Wikipedia

    en.wikipedia.org/wiki/Variable_pathlength_cell

    Variable pathlength absorption spectroscopy uses a determined slope to calculate concentration. As stated above this is a product of the molar absorptivity and the concentration. Since the actual absorbance value is taken at many data points at equal intervals, background subtraction is generally unnecessary.

  4. Absorbance - Wikipedia

    en.wikipedia.org/wiki/Absorbance

    Absorbance is defined as "the logarithm of the ratio of incident to transmitted radiant power through a sample (excluding the effects on cell walls)". [1] Alternatively, for samples which scatter light, absorbance may be defined as "the negative logarithm of one minus absorptance, as measured on a uniform sample". [2]

  5. Absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Absorption_spectroscopy

    Determining the absolute concentration of a compound requires knowledge of the compound's absorption coefficient. The absorption coefficient for some compounds is available from reference sources, and it can also be determined by measuring the spectrum of a calibration standard with a known concentration of the target.

  6. Beer–Lambert law - Wikipedia

    en.wikipedia.org/wiki/Beer–Lambert_law

    Absorbance within range of 0.2 to 0.5 is ideal to maintain linearity in the Beer–Lambert law. If the radiation is especially intense, nonlinear optical processes can also cause variances. The main reason, however, is that the concentration dependence is in general non-linear and Beer's law is valid only under certain conditions as shown by ...

  7. Bradford protein assay - Wikipedia

    en.wikipedia.org/wiki/Bradford_protein_assay

    The equation displayed on the chart gives a means for calculating the absorbance and therefore concentration of the unknown samples. In Graph 1, x is concentration and y is absorbance, so one must rearrange the equation to solve for x and enter the absorbance of the measured unknown. [25]

  8. Nucleic acid quantitation - Wikipedia

    en.wikipedia.org/wiki/Nucleic_acid_quantitation

    The ratio of the absorbance at 260 and 280 nm (A 260/280) is used to assess the purity of nucleic acids. For pure DNA, A 260/280 is widely considered ~1.8 but has been argued to translate - due to numeric errors in the original Warburg paper - into a mix of 60% protein and 40% DNA. [ 6 ]

  9. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]